Transport platform
SEP Serie
SEP u
ser’s manual Page 48 of 89
Doc no. RD-7243-MA-001-02
7.8.3. Descend
On the (
CC2
) control box.
∞
R
EFER TO SECTION
ON PAGE
•
The white "
BAS/DOWN"
button must be lit for the command to be available. If the
machine is at ground level, the button cannot be lit. If the white button does not light up,
check the green indicator lights on the (
CC1
) panel.
∞
R
EFER TO SECTION SECTION
ON PAGE
•
Press and hold the lit white "
BAS/DOWN"
button. If you release the button, the platform
will immediateley cease its lowering.
•
When approaching the desired level, still without releasing the white "
BAS/DOWN"
button, press and release the blue "
PROCHAIN ÉTAGE ARRÊT / NEXT FLOOR STOP"
button which will light up to confirm command. The plateform will automatically stop when
it will reach the next level or ground level (lowest level).
o
Note:
once pressed, the blue "
PROCHAIN ÉTAGE ARRÊT / NEXT FLOOR
STOP"
lights up.
o
Note:
If you release the white "
BAS/DOWN"
button before the platform stops
itself, the platform stops its ascension and the "
PROCHAIN ÉTAGE ARRÊT /
NEXT FLOOR STOP"
command is cancelled. If you resume your ascension by
pressing only the white button, the platform will continue to rise without stopping
at the next level.
•
When the platform stops, release the white "
BAS/DOWN "
button.
o
The white "
BAS/DOWN "
button turns off.
o
The white "
HAUT/UP "
button turns off.
o
The blue "
PROCHAIN ÉTAGE ARRÊT / NEXT FLOOR STOP"
turns off.
o
The yellow «
DÉBARRER PORTE/UNLOCK DOOR
» button lights up, meaning
the tailgate is unlocked.
Note:
Generally, if a button is not lit, the associated command is not available or not registered. If
both white buttons are not available, no platform movement is possible. Position of the platform,
unlocking of the doors or activation of a travel end detector may trigger the safety relay and stop
the buttons from lighting up.
Note:
During descent, when the platform reaches 10'-0" (3m) from the ground (platform floor and
loading level) the machine stops two (2) * seconds and a sound signal occurs. The sound signal
continues until the platform has reached the loading.
* Note * When within 10'-0" (3m) from ground descent zone, keep the «BAS/DOWN» pressed at
least two (2) seconds to give the machine time to activate descent.
Control box (CC2)
Summary of Contents for SEP-5000
Page 1: ......