FRAMA AG
CH-3438 LAUPERSWIL / BERN
TITLE:
SERVICE MANUAL
SUBJECT
:
AUTOMATIC FEEDER MATRIX AF / AFS
AUTHOR(S)
:
ROLAND BÄRTSCHI (BAER)
FILE:
PER_MAN_R0102_EN_SERVICE MANUAL AF_AFS.DOC
DOC. REF:
DOC.
R01.02
CREATED
:
31.10.13 16:10
MODIFIED
:
19.11.13 13:11
PAGE
17
OF 40
6.
Light barrier diagnostic test
During the start up procedure a check of all light barriers will be automatically performed. In case of an
occurring malfunction an error code will be displayed. It is possible to display the status of each light
barrier to facilitate the error searching. Therefore, press the service button as soon an error is displayed.
As an example, the following display should be displayed:
6.1.
Test Feeder Matrix AF / AFS
Figure 12: Service Diagnostic
S: Light barrier stack release switch
1 = Light barrier active
0 = Light barrier inactive
L: Sensor water level
0 = Light barrier active
(tank empty)
1 = Light barrier inactive
(tank full)
T: Light barrier water tank
0 = Light barrier active
(tank inserted)
1 = Light barrier inactive
(tank removed)
M: Sensor solenoid
0 = Light barrier active
(magnet falling
off)
1 = Light barrier inactive
(magnet
attracted)
B: Light barriers
Position: Letter table BA2
1 = Light barrier active
0 = Light barrier inactive
2. Position: Letter table BA1
1 = Light barrier active
0 = Light barrier inactive
E: Light barrier motor transmitters
1.
Transmitter motor transport
0 = Light barrier active
1 = Light barrier inactive
2. Transmitter motor separation
0 = Light barrier active
1 = Light barrier inactive
3. Transmitter motor intake
0 = Light barrier active
1 = Light barrier inactive
--F4/F6 service diagnostic--
Error E0004
S:1 L:0 T:0 M:1 B:01 E:010
S:0110 P:101 L:0 B :101 T:10
--F4/F6 service diagnostic--