background image

7- 

 

Fault Finding 

 

All fault finding must be conducted by a competent person or qualified Electrical Engineer. 

 
Failure of Lamp to light 

 
Causes

 
1)

 

Power not supplied; 

2)

 

Fuse blown; 

3)

 

Failed lamp 

 
Remedy

 
1)

 

Check voltage at supply. If supply is not present the fault is at the customer supply. If power is 

present, see remedy 2; 

2)

 

Check fuse for visual failure. If none noticeable check fuse for continuity using a multi-meter. If 

fuse found to be faulty, replace with new part and test equipment again for correct working 
order. If found to be working correctly see remedy 3; 

3)

 

Firstly, check supply at lampholder connecting block (within searchlight barrel). If supply is 
present, disconnect unit from power supply before removing the lamp. If noticeable damage to 

filament is present, the lamp will have failed. The lamp can also be checked for continuity using 
a multi-meter. Replace lamp ensuring all precautions and instructions previously outlined in 

this manual are adhered to. 

 
Failure of Remote Focus 

 

Causes
 

1)

 

Power not supplied; 

2)

 

Faulty connections; 

3)

 

Failed motor/transformer 

 

Remedy
 

1)

 

Check voltage at supply. If no supply present fault is at customer supply. If power is present 
see remedy 2; 

2)

 

Check all wiring connections on motor, transformer and terminal rail, in accordance with the 
wiring diagram. If found to be correct, see remedy 3; 

3)

 

Remove focus motor and apply 24v DC directly across terminals. If motor does not rotate the 
unit has failed. A new focus motor should be fitted to the lampholder assembly. If the motor is 

working correctly, check output of transformer (mounted in the Motor Gearbox).  

 

NOTE: If a fault occurs on the pan and tilt gearbox, the unit should be returned to Francis 

Searchlights Limited for fault evaluation and repair. 

Back To Top

Summary of Contents for FR560

Page 1: ...ht Product Reference Number A2474 FR560RC 115 240v 1Kw Manufacturers details Distributor details Francis Searchlights Ltd Union Road Bolton Lancashire BL2 2HJ UK Tel 44 0 1204 558960 Fax 44 0 1204 558...

Page 2: ...ty Precautions 3 Technical Information 4 Unpacking and Installation Instructions 5 Electrical Installation 6 Operating Instructions 7 Fault Finding 8 Maintenance and Servicing 9 Wiring Diagrams Genera...

Page 3: ...ptimum performance and service life The Francis FR range combines features proven over many years service in the most hazardous conditions in both marine and land installations In order to prolong the...

Page 4: ...re a safe working environment Never attempt to clean a lamp whilst in use Searchlights get hot Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the search...

Page 5: ...internal heater Optional Toughened front glass The searchlight also performs to the following optical data 1000 Watt T H Supply voltage 220 240v or 110 115v Peak Beam Candlepower 2 450 000 lux Range 1...

Page 6: ...pply before being installed Installation procedures should be adhered to in order to ensure a safe working environment and reduce the risk of damage or personal injury Preparing the Mounting Position...

Page 7: ...be made in the cable size in order to overcome the voltage drop The following table should be used for indication purposes only Searchlight FR 115v 1Kw 230v 1Kw Cable Size mm Distance Max Distance Ma...

Page 8: ...from the gearbox to junction box provided Cables required to be connected by the customer 5 core 1 5mm cable from the Junction Box to the Control Panel 12 core 0 5mm cable from the Junction Box to the...

Page 9: ...ich it was designed Any modifications to the product should not be undertaken without consulting the manufacturer Setting to Work Safe service in use necessitates the strict observance of the followin...

Page 10: ...orrect power rating and type Check lampholder is in good condition If the contacts show any sign of corrosion replace the lampholder Check the lampholder is in a good dry condition Never allow water t...

Page 11: ...with leads Ammeter Using the equation P VI the approximate power output of the equipment can be calculated in the following way Using the multi meter take a voltage reading Using the ammeter take an...

Page 12: ...amp will have failed The lamp can also be checked for continuity using a multi meter Replace lamp ensuring all precautions and instructions previously outlined in this manual are adhered to Failure of...

Page 13: ...g a proprietary glass cleaner or metal polish Clean the reflector if required Check the reflector mounting gaskets If signs of corrosion or damage are evident replace as necessary Ensure that the lamp...

Page 14: ...ng Diagrams and General Assembly Drawing Number Description C22606 Wiring Diagram 1Kw RC V S 10 Amp A2474 FR560RC 1Kw General Assembly drawing Control Panel Assembly C23604 Junction Box Assembly Back...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...Back To Top...

Page 19: ...V Mount C20281 00 Bellows Motor Gearbox Spares C22403 01 Pan Motor S Assy C22287 00 Tilt Motor C22380 00 Microswitch no leaver C22382 00 Microswitch with leaver C24030 01 I Drive Pan Speed Controller...

Reviews: