10 - Spare Parts List 

 

The following spare parts can be ordered directly from the manufacturer: 

 
 

Part Number 

Description 

        Searchlight Spares 
 

 

 

D1809 

115v 1Kw GX9.5 Tungsten Halogen Lamp 

 

D6715 

220v 1Kw GX9.5 Tungsten Halogen Lamp 

 

D1813 

240v 1Kw GX9.5 Tungsten Halogen Lamp 

 C03022-00 

Lampholder 

GX9.5 

1Kw 

 

C14143-00 

Switch 10A 1Kw- On/Off 

 

C14142-00 

Switch – Focus 

 C22347-00 

Joystick 

 C22491-00 

Switch 

(Controller/Speed) 

 C20286-00 

Front 

Glass 

 

C20287-00 

Front Glass Gasket 

 

C16410-00 

Motor - Remote Focus 

 C05396-00 

Reflector 

 C20070-00 

Drainage 

Plug 

 C22268-01 

Breather 

Assy 

 C16761-00 

A.V. 

Mount 

 C20281-00 

Bellows 

Motor Gearbox Spares 

 

 

C22403-01 

Pan Motor S/Assy  

 

C22287-00 

Tilt Motor  

 

C22380-00 

Microswitch no leaver 

 

C22382-00 

Microswitch with leaver 

 C24030-01 

‘I’ 

Drive 

Pan Speed Controller 

             C24060-01                      ‘I’ Drive Tilt Speed Controller 

 C23530-01 

P.S.U 

 

C22381-00 

Pedestal Top Sealing Gasket 

 

C26185-00 

Pedestal Cover Gasket 

 

In order to prolong the life and performance of your product, we recommend that you only specify 

Francis Searchlights spare parts. This will ensure that any warranties on your equipment will not be 
invalidated. 

When ordering spare parts please contact the Sales Department at Francis Searchlights Limited. 
Please quote searchlight model and serial number at all times. This will enable a fast response to 

your spares’ requirements. 

                                                                

Back To Top

Summary of Contents for FR560

Page 1: ...ht Product Reference Number A2474 FR560RC 115 240v 1Kw Manufacturers details Distributor details Francis Searchlights Ltd Union Road Bolton Lancashire BL2 2HJ UK Tel 44 0 1204 558960 Fax 44 0 1204 558...

Page 2: ...ty Precautions 3 Technical Information 4 Unpacking and Installation Instructions 5 Electrical Installation 6 Operating Instructions 7 Fault Finding 8 Maintenance and Servicing 9 Wiring Diagrams Genera...

Page 3: ...ptimum performance and service life The Francis FR range combines features proven over many years service in the most hazardous conditions in both marine and land installations In order to prolong the...

Page 4: ...re a safe working environment Never attempt to clean a lamp whilst in use Searchlights get hot Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the search...

Page 5: ...internal heater Optional Toughened front glass The searchlight also performs to the following optical data 1000 Watt T H Supply voltage 220 240v or 110 115v Peak Beam Candlepower 2 450 000 lux Range 1...

Page 6: ...pply before being installed Installation procedures should be adhered to in order to ensure a safe working environment and reduce the risk of damage or personal injury Preparing the Mounting Position...

Page 7: ...be made in the cable size in order to overcome the voltage drop The following table should be used for indication purposes only Searchlight FR 115v 1Kw 230v 1Kw Cable Size mm Distance Max Distance Ma...

Page 8: ...from the gearbox to junction box provided Cables required to be connected by the customer 5 core 1 5mm cable from the Junction Box to the Control Panel 12 core 0 5mm cable from the Junction Box to the...

Page 9: ...ich it was designed Any modifications to the product should not be undertaken without consulting the manufacturer Setting to Work Safe service in use necessitates the strict observance of the followin...

Page 10: ...orrect power rating and type Check lampholder is in good condition If the contacts show any sign of corrosion replace the lampholder Check the lampholder is in a good dry condition Never allow water t...

Page 11: ...with leads Ammeter Using the equation P VI the approximate power output of the equipment can be calculated in the following way Using the multi meter take a voltage reading Using the ammeter take an...

Page 12: ...amp will have failed The lamp can also be checked for continuity using a multi meter Replace lamp ensuring all precautions and instructions previously outlined in this manual are adhered to Failure of...

Page 13: ...g a proprietary glass cleaner or metal polish Clean the reflector if required Check the reflector mounting gaskets If signs of corrosion or damage are evident replace as necessary Ensure that the lamp...

Page 14: ...ng Diagrams and General Assembly Drawing Number Description C22606 Wiring Diagram 1Kw RC V S 10 Amp A2474 FR560RC 1Kw General Assembly drawing Control Panel Assembly C23604 Junction Box Assembly Back...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...Back To Top...

Page 19: ...V Mount C20281 00 Bellows Motor Gearbox Spares C22403 01 Pan Motor S Assy C22287 00 Tilt Motor C22380 00 Microswitch no leaver C22382 00 Microswitch with leaver C24030 01 I Drive Pan Speed Controller...

Reviews: