2.5.Assembly of flue spigot and blanking
plates
The stove is supplied with a connection flue spigot with
an inner Ø of 125 mm or external Ø 139 mm.
2.5.1. Smoke exit at rear
Figure 6
- Check that the two blanking plates (# A & C) are fixed
to the cast iron top.
- Lift the cast iron top from the stove (fig. 3).
- Remove the internal baffle (# 56, page 23) and the
rear heat shield (# 27, page 23).
- Fix the sealing rope (# D) in the groove and fit the flue
spigot (# B), ensuring there is a good seal.
- Replace the internal baffle and re-fit the cast iron top.
- Remove the cut-out in the rear heat shield (fig. ) and
re-fit.
2.5.2. Smoke exit on the top
Figure 7
- Lift the cast iron top from the stove (fig. 3).
- Remove the two blanking plates (# A & C).
- Fit the sealing rope (# D) in the groove and attach the
flue spigot (# B) using the three bolts and washers
supplied.
- Remove the internal baffle (# 56, page 23) and the rear
heat shield (# 27, page 23).
- Position the sealing rope (# D) in the groove on the
rear aperture of the stove and fit the two blanking plates
(# A & C).
- Replace the internal baffle and the cast iron top.
2.6. Fitting of the handle
In order to avoid the damaging of the threading, first put
the handle in operating position then screw it into the
taping of the lock (fig. 8).
Technical manual “701”
17
“Le Franc-comtois” - ref. 134 07 01
Installation instructions
Figure 5 - Removing blanking plate on rear heat
shield
Figure 6 - Smoke exit at rear
A
: Blanking plate
B
: Flue collar
C
: Clamp
D
: Ceramic rope
A
C
(6x20)
B
D
Figure 7 - Smoke exit from top
A
: Blanking plate
B
: Flue collar
C
: Clamp
D
: Ceramic rope
A
C
(6x20)
B
D
Figure 8 - Fitting of the handle