32
5.3
Working pressures and spray flow rates
Infinite pressure and flow rate regulation by means of overflow safety valves. Set desired
operating stage on the handwheel of the overflow safety valve:
Admissible nozzles;
Identifcation
Jet shape
Angle
Flow rate
l/min
Working
pressure
bar
Recoil
force
N
FC 711 M
0005
Full jet
-
11,5
115
20
1505
Flat jet
15 °
2505
Flat jet
25 °
4005
Flat jet
40 °
5005
Flat jet
50 °
6505
Flat jet
65 °
FC 1024 M / MP / TCA
00045
Full jet
-
17,0
240
48
15045
Flat jet
15 °
25045
Flat jet
25 °
40045
Flat jet
40 °
50045
Flat jet
50 °
65045
Flat jet
65 °
Working pressure
Flow rate
FC 711 M
115
11,5
90
10,0
70
9,0
50
7,5
FC 1024 M / MP / TCA
240
17,0
190
15,0
140
13,0
90
10,5
50
7,5
Summary of Contents for FC 1024 M
Page 2: ...2...
Page 8: ...8 MP Ausf hrung TCA Ausf hrung...
Page 27: ...27 UK MP Variant MP Variant...
Page 41: ...41 UK...
Page 44: ...44...
Page 45: ...45 UK...
Page 46: ...46...
Page 47: ...47 UK...