20. Replacing the Functional Part
20.1
Close the water volume regulator (see
20.2
Trigger the fitting.
20.3
Remove the cover plate (a).
20.4
Use an Allen key to unscrew the screw (b) counter-clockwise.
20.5
Remove the rotary knob (c).
20.6
Use an Allen key to unscrew the screw (d) counter-clockwise.
20.7
Pull off the control unit (e).
20.8
Remove the circlip.
20.9
Pull out the functional part.
20.10
Reassemble in the reverse order.
20.11
Check the flow duration and correct if necessary (see
21. Adjusting the Key Stroke
21.1
Remove the cover plate (a).
21.2
If the key (b) has too much play, turn the screw (c) clockwise.
21.3
If water flows continuously, turn the screw (c) counter-clockwise.
21.4
Trigger the fitting.
21.5