6
ZMI
_001_
2000
0659
57-A
Q
RM668
_#SE
N
_#AQ
U
_#V5
.f
m
11.5
Remove the pressure cap and the spring.
11.6
Use a socket spanner to remove the functional part.
11.7
Reassemble in the reverse order.
11.8
Check the flow duration and correct if necessary (see
12. Fault Correction
If you are unable to correct a fault, or if the fault is not described in the table, please
inform the customer service department.
13. Replacement Parts
Fault
Cause
Remedy
Valve does not open
– Stop valve is closed
– Functional part faulty
➯
Open it
➯
Replace it
Valve does not close
– Functional part faulty
➯
Replace it
Water flow too weak
– Shower head/outlet is clogged with dirt
– Supply pressure too low
– Water volume regulator is not fully opened
➯
Cleaning
➯
Check it
➯
Open it
Flow duration too
short or too long
– Incorrect setting
– Shower head/outlet is clogged with dirt
– Functional part faulty
➯
Adjust it
➯
Cleaning
➯
Replace it
Designation
Order No.
1 Pressure cap. . . . . . . . . . . . . . . . . 2000104784
1a Cover platelet . . . . . . . . . . . . . . . . 2000104841
2 Functional part
Shower systems . . . . . . . . . . . 2000104352
Washing bays . . . . . . . . . . . . . 2000104372
3 Valve seat with O-ring . . . . . . . . . . 2000104790
4 Slide-on rosette . . . . . . . . . . . . . . 2000104892
Spare parts kit consisting of:
Rubber parts
Pressure spring
Circlip . . . . . . . . . . . . . . . . . . . 2000104804