EN
FMA 839 HI / FMA 839 HI LL KIT
– 26 –
E6
The power supply
voltage does not fall
within the range (voltage
and/or frequency). The
cooking area cannot be
activated
The power supply voltage
does not fall within the
range (see technical data
for details).
Check the mains voltage.
Internal error in generator
circuits.
Replace the module.
E7
TC internal error. The
cooking areas are
deactivated.
-
Replace the module.
E8
Suction hood
malfunction.
The suction hood is blocked.
Clean and remove any blocks.
Faulty fan or electronic
module.
Replace the module.
E9
Cooking area
temperature sensor
error. The corresponding
cooking area is Off.
The temperature sensor
circuit is open or there is a
short-circuit.
Replace the inductor.
EA
TC internal error. The
cooking areas are Off.
-
Replace the generator.
EH
Temperature sensor
blocked. The
corresponding cooking
area is Off.
No change in temperature
(min. 10 K / 5 min.) after
activation of the cooking
area.
Replace the inductor.
TC =
TOUCH CONTROL
UI =
USER INTERFACE
NTC =
TEMPERATURE SENSOR
Summary of Contents for MARIS FMA 839 HI