– 9 –
TE-45
/ TE-50 / TE-75 / TE-75S / TE-125 / TE-125BF
EN
countertop and at a minimum of one meter from
the side of the sink, away from water splashes
and out of the reach of children. This spur switch
must be a double pole with at least 3 mm contact
separation in each pole. 20 Amp DP switches BS
3676 meet this condition.
9
To avoid accidentally leaving the disposer running,
a switch with a neon indicator lamp is suggested.
9
A 13 Amp ASTA approved fuse, to BS 1363 must
be fitted in the fuse carrier of this spur switch.
ELECTRICAL CONNECTIONS:
X
X
Simply insert the plug into the socket wired as
previously described.
WHEN NOT USING THE PRE-WIRED PLUG BUT
WIRING DIRECT WITH FIXED WIRING (fig.
3B
).
9
The switches used must be double pole type and
have at least a 3 mm contact separation in each
pole (20 Amp DP switches to BS 3676 meet this
requirement).Prepare the tips of the wires of the
electrical lead and attach to the junction box.
9
Disconnect the junction box from the electrical
supply before making the following connections:
9
The green and yellow wire must be connected to
the terminal marked in one of the following ways:
– with the letter “
E
”
– by the earth symbol (
)
– coloured green or green and yellow.
9
The brown wire must be connected to the
terminal that is marked with the letter „
L
“.
9
The blue wire must be attached to the terminal
that is marked with the letter „
N
“.
(
NOTE
: As your disposer has a molded plug on the
lead and the plug is not to be used, cut it off and
dispose of it wisely. A moulded plug with a loose
lead with disconnected wires can be hazardous as
an
electrical shock hazard
could occur should such
a plug be inserted into a 13 Amp socket anywhere
within the home.)
IS THE DISPOSER EARTHED?
WARNING:
this appliance
must be earthed
!
In the event of a malfunction of breakdown,
earthing reduces the
risk of shock
. This disposer
must be connected to an earthed, metal, permanent
wiring conductor and connected to the equipment
earthing terminal or lead on the disposer.
PLUG SOCKET
13 AMP FUSED
DOUBLE POLE
SWITCHED SPUR
WALL MOUNTED
ELECTRICAL CONNECTION
FOR DISPOSER PROVIDED
WITH PREWIRED MOLDED
PLUG AND LEAD.
For continuous feed only
- not batch feed
3A
13 AMP FUSED
DOUBLE POLE
SWITCHED SPUR
WALL MOUNTED
FIXED WIRE ELECTRICAL
CONNECTION
13 AMP FUSED
SPUR MOUNTED
UNDER SINK
3B
Replacing the fuse in moulded plugs
9
The correct fuse cover must be refitted when
changing the fuse.
9
Remove the fuse cover and slide the fuse out.
9
Replace it with a 13 Amp ASTA fuse (approved
to BS 1363). Should the fuse cover be lost or
damaged, an exact replacement should be used.
These are available from an approved service
agent, listed below. Never use the plug without
the fuse cover fitted.