10  Warranty

11  Liability

12  Disposal

Deviating from the applicable GTCs, the manufacturer grants a warranty of 24 months from the time of completion of the installation 
for the profi-air defroster heating DN 125. Warranty claims can only be asserted for material and/or construction defects occurring  
within the warranty period. In case of a warranty claim, the profi-air defroster heating DN 125 may not be removed without the prior 
written consent of the manufacturer.

Warranty expires if

 

Q

the warranty period ends. 

 

Q

the heating spiral has not been maintained and cleaned acc. to Section 8. 

 

Q

parts not provided by the manufacturer are installed.

 

Q

unauthorised changes or modifications are made to the unit.

The profi-air defroster heating DN 125 has been developed and produced for applications in so-called comfort ventilation systems.  
Any other application is considered “improper” and can lead to damage to the defroster heating or personal injury which the  
manufacturer cannot be held liable for.

The manufacturer is not liable for damage attributed to the following causes:

 

Q

Failure to comply with the safety, operating and maintenance instructions stated herein.

 

Q

Installation of spare parts not provided or stipulated by the manufacturer. 
The responsibility for the use of such spare parts rests solely with the installer.

 

Q

Normal wear and tear. 

In addition, our “General Terms and Conditions” apply as amended, available at www.fraenkische.com.

Please do not dispose of the profi-air defroster heating DN 125 with the normal household waste; please ask your municipal waste  
consulting authority about collection points and recycling possibilities.

Installation / operating instructions – defroster heating profi-air DN 125

14

Summary of Contents for Profi-air DN 125

Page 1: ...Defroster heating profi air DN 125 Installation operating instructions Building Technology www fraenkische com...

Page 2: ...Installation operating instructions defroster heating profi air DN 125 2...

Page 3: ...al related or other technological requirements which cannot or can no longer be considered in this publication For this reason we cannot assume any liability which is based solely on the data provided...

Page 4: ...instructions have to be complied with non compliance may result in personal injury and or damage to the profi air defroster heating 1 2 1 Safety regulations 1 2 2 Safety equipment and measures Q Inst...

Page 5: ...coil must be connected to the profi air 180 flat control This control ensures that the defroster heating only operates if there is a risk that the cross flow heat exchanger can freeze The profi air d...

Page 6: ...r plugs Q Heating performance 900 W Q Power consumption 4 1 A Q Safety components 1x safety temperature monitor 1x safety temperature limiter integrated into the circuit of the heater coil Q Air volum...

Page 7: ...on flammable pipe DN 125 with a minimum length of 300 mm must be installed downstream of the defroster heating Failure to comply with the safety instructions can lead to injury or property damage e g...

Page 8: ...case of vertical installation of the defroster heating a non flammable pipe with a minimum length of 300 mm must be connected downstream of the heater coil The pipe must be provided with non flammable...

Page 9: ...at 7831 2830 FR NK ISCHE ROHRW ERKE Gebr Kirchne r GmbH Co KG 97486 K nigsb erg Bay ern Tel 49 9525 88 2555 Fax 49 9525 88 2153 info gb_ h frae nkische de www fra enkisch e com Air Luft flow Air Luft...

Page 10: ...e rg Bayer n Tel 49 9525 88 2555 Fax 49 9525 88 2153 info gb_h fraenk ische de www frae nkische com Air Luft flow only if unit vertically mounted nur wenn Ger te vertikal montiert kun hvis aggregat mo...

Page 11: ...h Pa Airf l o w A B US B Air Luft flow B Rech tsver sion B Righ t unit unit destr a P1 P3 P4 P2 P1 P2 Pa P3 P4 m 3 Pa m 3 Eins tellw erte Cali brat i o n Cali braz i o ne 0 120 100 80 60 40 20 110 90...

Page 12: ...In addition applicable local regulations and safety provisions must be complied with 8 Maintenance and cleaning B Rech tsver sion B Righ t unit unit destr a P1 P3 P4 P2 P1 P2 Pa P3 P4 m 3 Pa m 3 Eins...

Page 13: ...resh air for apartments and residential buildings The product complies with the regulations particularly the protection requirements of the following EU directives Low Voltage Directive 2014 35 EU EMC...

Page 14: ...oped and produced for applications in so called comfort ventilation systems Any other application is considered improper and can lead to damage to the defroster heating or personal injury which the ma...

Page 15: ...Notes Installation operating instructions defroster heating profi air DN 125 15...

Page 16: ...o change without notice Cat no 5000 1340 00 01 2018 FR NKISCHE Rohrwerke Gebr Kirchner GmbH Co KG Hellinger Str 1 97486 K nigsberg Germany Phone 49 9525 88 2200 Fax 49 9525 88 92200 marketing fraenkis...

Reviews: