23
Fhoton™ Drive Specifications
Absolute maximum input voltages
NOTE: Suitable for use on a photovoltaic circuit capable of delivering not more than 50 DC amps short circuit current.
581011100984-XXXXX
581013000864-XXXXX 581014200864-XXXXX
110 VDC, operational limit
300 VDC, open circuit
420 VDC, open circuit
0.37 kW model*
0.55 kW model*
1.1 kW model*
Controller Model No.
581011100984-XXXXX
581013000864-XXXXX
581014200864-XXXXX
Output
Output voltage, nominal
48 VAC, 3-phase
100 V AC, 3-phase
200 V AC, 3-phase
Max Amps (RMS)
9.8A, each phase
8.6 A, each phase
6.8 A, each phase
Output Frequency
20-60 Hz (adjustable)
Efficiency at Max Power
98%
Absolute Maximum Input Voltage
PV DC
110 V, Operational Input limit
300 V, open circuit
420 V, open circuit
PV source
Input Voltage
*40 - 110 VDC
*45 – 300 V DC
*115 – 420 V DC
Max. Amps Input
7.2 A DC, continuous
7.2 A DC, continuous
6.2 A DC, continuous
Power
Up to 600 W
Up to 1200 watts
Up to 2000 watts
Controller Size L x W x D
Millimeters
159.5 x 159.5 x 102.1 mm
Inches
6.28" X 6.28" X 4.02"
Operating Conditions
Temperature Range
-25 °C to 50 °C Max.
-13 °F to 122 °F Max.
Relative Humidity Range
0 to 100% Condensing
Enclosure Type
Type 4
Table 7: Fhoton™ Drive Specifications
* 45 and 115 VDC for the 0.55kW and 1.1 kW models respectively should not be interpreted as an adequate rated PV array output voltage for any installation.
See the PV Solar Array Specifications and System Sizing program for indication of adequate array voltage to provide useful pumping capability.