SECTION I. INTRODUCTION 

 

Congratulations, you have just purchased the 
replacement filter for the HMX-1 and ARS-1 heavy 
metal reduction systems.   

 

Your new Heavy Metal Reduction Drinking Water 
cartridge (HMRC10) uses a non-leaching material 
to reduce unwanted arsenic 3, arsenic 5, lead, 
cadmium, copper, antimony, mercury, zinc, nickel 
and selenium in a water supply. The HMRC10 
cartridge should only be used with the HMX-1 or 
ARS-1 drinking water systems.  This filter is not to 
be used with any other system due to heavy metal 
contaminant bleed through that could occur.  Have 
your water checked periodically to verify heavy 
metal reduction.

 

LIABILITY 

 

All information and recommendations appearing in this manual 
concerning the use of products described herein are based on 
information contained in good faith but makes no representation as to its 
comprehensiveness or accuracy. However, it is 

the user’s responsibility to 

determine the suitability for his own use of such products. Since the actual 
use by others is beyond our control, no guarantee, expressed or implied, is 
made by Franklin Electric Co., Inc. as to the effects of such use or the 
results to be obtained. Franklin Electric Co., Inc. assumes no liability arising 
out of the use by others of such products. Nor is the information herein to 
be construed as absolutely complete, since additional information may 
be necessary or desirable when particular or exceptional conditions or 
circumstances exist or because of applicable laws or government 
regulations.

 

 

 
 
 

 
 
 
 
SECTION II. 

SPECIFICATIONS

  

 

TABLE A 

– RECOMMENDED OPERATING LIMITS FOR FEED WATER

 

 

Specifications 

 

 

 

 

HMRC10 

Water Pressure 

 

 

 

 

40-100 psig  

Temperature   

 

 

 

 

40-100°F  

pH 

 

 

 

 

 

 

5.0-8.0 (lower pH is favorable for arsenic reduction) 

Hardness 

 

 

 

 

 

More than 5 gpg* 

Iron 

 

 

 

 

 

 

Less than 0.1 ppm (also mg/l) 

Manganese 

 

 

 

 

 

Less than 0.01 ppm (also mg/l) 

Total Heavy Metal Contaminant 

 

 

Less than or equal to 100 ppb (0.10 ppm or mg/l) 

Silica   

 

 

 

 

 

Less than  30 ppm (also mg/l) 

Bacteria 

 

 

 

 

 

Must be potable** 

IMPORTANT: The HMRC10 may be installed on waters containing heavy metals listed in Section I.; however, the total heavy 
metal concentration of the incoming water supply must be less than or equal to 100.0 ppb.  Installing this unit on water with 
greater than 100.0 ppb of heavy metals may result in harmful heavy metal bleed through in excess of the MCL established by 
the EPA.  I.E. arsenic MCL = 10 ppb, lead MCL = 15 ppb. 

 

Have your water checked periodically to avoid harmful levels of heavy metal bleed through! 

Satisfactory test results will be less than or equal to the MCL established by the EPA! 

 

*Does not require softened water.  Calcium aids in the adsorption of heavy metal on the filter material and 

protects it from being fouled by silica.  The HMRC10 works with softened water, but if silica is present 
performance and life of cartridge will be significantly reduced.  If the water is soft, preceding the unit with a 
reverse osmosis system provides the ideal water quality to ensure optimal performance.  

 
**DO

 

NOT

 

USE

 

WITH

 

WATER

 

THAT

 

IS

 

MICROBIOLOGICALLY

 

UNSAFE

 

OR

 

OF

 

UNKNOWN

 

QUALITY. 

HMRC10 CARTRIDGE REPLACEMENT FOR HMX-1 & ARS-1

 

Recommended Filter Change Schedule* 

  

ARSENIC:   

<=60ppb                1,800 gallons 
<=70ppb                1,500 gallons 
<=90ppb                1,200 gallons 
<=100ppb              1,000 gallons 

>100ppb      Not Recommended 

 

LEAD:   

<=100ppb              1,800 gallons 

>100ppb      Not Recommended 

 

Periodically test treated water for contaminant level! 