background image

 

G. Start up the System

 

 

1)  Double check that all connections are 

secure. 

2)  Turn on feed water valve and check for 

leaks. If any leaks are noted, turn off valve 
and correct before proceeding. 

3)  Turn on ball valve and open faucet until a 

steady stream of water flows.  Close faucet, 
wait at least 5 minutes and carefully check 
for leaks. Correct as necessary. 

 

H. Flush System and Check Operation

 

 

1)  Lift faucet handle and allow NRS-1system 

to flush 1-2 gallons down the drain or flush 
system until water runs clear.  The flushed 
water should be discarded. 

 

SECTION V. OPERATION & 
MAINTENANCE 

 
A.  Changing Filter 
 

NOTE: THIS NRS-1 SYSTEM CONTAINS A 
FILTER WHICH MUST BE REPLACED AT 
REGULAR INTERVALS TO MAINTAIN PROPER 
PERFORMANCE. USE ONLY FACTORY 
APPROVED FILTERS. 

 

Please see Page 3 for the recommended interval 
for changing the filters. Local conditions may 
dictate more frequent changes. 
 

NOTE: The system should be sanitized before 
installing the replacement cartridge. 

 
Use a drip pan to catch any water that may spill 
when the filter housings are removed: 

1)  Close the Ball Valve on the INLET of the 

housing and push the red button on top of 
the housing to relieve the operating 
pressure.  

2)  Loosen and remove the Filter Housing with 

the provided wrench. Discard the cartridge.     
NOTE: Exhausted filter cartridge may be 
disposed by normal means. Dispose as 
nonhazardous solid waste. 

3)  Wash the inside of the Housing(s) using a 

mild detergent and a soft cloth.  Do not use 
abrasive cleaners or pads. Thoroughly rinse 
all soap from the housing before 
reassembly. 

4) 

To sanitize the system and replace the filter 
cartridge(s): 

 

a)  Use a good quality unscented 5-1/4% 

liquid bleach. 

b)  Add one cap full of bleach (this is 2 tsp. 

or 10 ml) to the filter housing.  

c)  Turn the water meter to any number of 

gallons to allow for water flow. 

d)  The dispensing faucet should be open, 

slowly open the ball valve on the feed 
water line. 

e)  As soon as water begins to drip out of 

the dispensing faucet, close the faucet. 

f)  Let the system stand for 15 minutes. 
g)  At the end of the 15 minutes, in the 

following order, open the ball valve; 
open the dispensing faucet to allow 
purging of the chlorine to the drain. 

h)  Reset the automatic shut-off meter to 

the number of gallons recommended on 
page 3. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for NRS-1

Page 1: ...1 INSTALLATION MANUAL NRS 1 Point of Use Nitrate Reduction System Franklin Electric Co Inc 12630 US 33 N Churubusco IN 46723 Ph 260 693 1972 Fax 260 693 0602 NRS 1 Manual 211215...

Page 2: ...Faucet Mounting Hole 5 2 Mount the Faucet 6 B Install the Feed Water Valve and Tubing 6 C Automatic Water Meter 7 D Setting the Shut off Meter 7 E Make Final Tubing Connections Install the Leak Stop V...

Page 3: ...tely complete since additional information may be necessary or desirable when particular or exceptional conditions or circumstances exist or because of applicable laws or government regulations SECTIO...

Page 4: ...nd a hole will have to be made from inside the cabinet through the floor to the basement Never install in an area of the home where temperature is freezing as damage to the system will result If a rev...

Page 5: ...ucet Installation Diagram The faucet should be positioned so that it empties into the sink and the spout swivels freely for convenience If the sink already has a hole provided that can accommodate the...

Page 6: ...ns that it is always in a sharpened condition Dull cutters are known to chip sinks 2 Mount the Faucet a Familiarize yourself with all components shown in faucet diagram b Disassemble hardware from the...

Page 7: ...er reset See Changing Filter for filter replacement procedure E Make Final Tubing Connections With all of the components in place the final tubing connections can be made When routing tubing between c...

Page 8: ...housings are removed 1 Close the Ball Valve on the INLET of the housing and push the red button on top of the housing to relieve the operating pressure 2 Loosen and remove the Filter Housing with the...

Page 9: ...ector tube X MNPT 5 USH10 white housing cap 10 with bracket wrench 6 ASO 14 Automatic shut off 1 800 gallons cap 7 4FC4 NPT Female connector tube X FNPT 8 WR200 Wrench for USH included with housing 9...

Page 10: ...surface nicks or scratches If it is necessary to cut the tubing use a plastic tubing cutter or sharp razor knife Make a clean square cut An optional blue locking clip is installed in certain fittings...

Page 11: ...es have not been met NRC10 cartridge capacity has been exhausted Install required pre treatment equipment Note the number of gallons that have been used since the cartridge was installed Replace the c...

Page 12: ...ove the expanded pellet from the retainer 3 Replace the expanded pellet with the spare compressed pellet 4 Seat the compressed pellet and retainer into the lower body 5 Push the upper cover down until...

Page 13: ...labor charges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover The above warranty will not apply to any part of the Nitrate Drinking Wa...