12
Generator Sizing
Basic generator sizing for the SubDrive Connect system is 1.5 times the maximum input watts consumed
by the drive, rounded up to the next normal-sized generator.
Recommended minimum generator sizes:
Model
Generator Watts
SubDrive 15
3500
SubDrive 20
5700
SubDrive 30
7000
SubDrive 50
11000
IMPORTANT:
Do not use with a Ground Fault Circuit Interrupter (GFCI). If using an externally regulated
generator, verify that the voltage, hertz, and idle speed are appropriate to supply the drive.