54
Condition
Display
Possible Cause
Corrective Action
Low
Pressure
Green
Motor
Frequency
•
Pressure sensor setting,
pump rotation, pump sizing
•
High temperature
•
Adjust pressure sensor, check pump rotation.
•
Check frequency at max flow, check max pressure
•
High ambient and/or drive temperature will cause drive to fold-
back power and run with reduced performance
High
Pressure
Green
Motor
Frequency
•
Pressure sensor setting
•
Shorted sensor wire
•
Adjust pressure sensor
•
Verify condition of sensor wire and repair.
•
Remove sensor wire at Pressure Input Board.
1.
if drive stops running, wire may be shorted
2. if drive continues to run, replace Pressure Input Board
3. If drive continues to run after replacing Pressure Input board,
replace drive
Audible
Noises
Green
Motor
Frequency
•
Fan
•
Hydraulic
•
Plumbing
•
For excessive fan noise, replace fan
•
If fan noise is normal, drive will need to be relocated to a more
remote area
•
If a hydraulic problem, try raising or lowering depth of pump
•
Pressure tank location should be at entrance of water line into
house
No Display
None
•
Display board cable discon-
nected or loose
•
Verify cable connection between main control board and display
Cannot Con-
nect to Drive
Bluetooth
FE Connect
Light On
Soid
•
Attempting to connect to
incorrect drive
•
Out of Wi-Fi range of drive
(more than 100 ft line-
ofsite)
•
Ensure the Wi-Fi SSID (hotspot name) you are connecting to
matches the correct drive
•
Move so Wi-Fi signal is closer to the drive if walls or floors are
between you and the drive
•
Wi-Fi module not responding, cycle power to drive
•
Cycle Wi-Fi radio on mobile device, refresh Wi-Fi connection list
FE Connect
Light Off
•
Wi-Fi timeout expired
•
If more than fifteen (15) minutes since last power cycle, cycle
power to drive
•
If more than one (1) hour since last disconnection from Wi-Fi,
cycle power to drive
RFI-EMI
Interference
Green
Motor
Frequency
•
Poor grounding
•
Wire routing
•
Adhere to grounding and wire routing recommendations
•
An additional external filter may be needed.
System Reg-
ulates but
displays
199P
Green 199P
•
The pressure in the system
is 199 psi or higher
•
The max pressure the display can show is 199 psi. Use the pres-
sure gauge or Wi-Fi / FE-Connect app to view the system
pressure.
Summary of Contents for SubDrive 15
Page 1: ...S SU UB BD DR RIIV VE E C CO ON NN NE EC CT T Owner s Manual ...
Page 14: ...14 ...
Page 22: ...22 ...
Page 30: ...30 ...
Page 36: ...36 ...
Page 40: ...40 ...
Page 56: ...56 ...
Page 62: ......
Page 63: ...ESPAÑOL ES franklinagua com SUBDRIVECONNECT Manual para propietarios ...
Page 70: ...8 ...
Page 78: ...16 ...
Page 84: ...22 ...
Page 88: ...26 ...
Page 96: ...34 ...
Page 102: ...40 ...
Page 106: ...44 ...
Page 128: ......
Page 129: ...franklinwater com FRANÇAIS FR SUBDRIVECONNECT Manuel du propriétaire ...
Page 136: ...8 ...
Page 144: ...16 ...
Page 150: ...22 ...
Page 154: ...26 ...
Page 162: ...34 ...
Page 168: ...40 ...
Page 172: ...44 ...
Page 194: ...REMARQUES ...
Page 195: ...REMARQUES ...
Page 196: ......