6
1-1/2”
GALVANIZED
PIPE
WELL POINT
CHECK
VALVE
1-1/2” RIDGED
PVC PIPE
1-1/2 RIDGED
PVC PIPE
1-1/2” PVC
ADAPTER
1-1/2” FOOT
VALVE
1-1/2” PVC
ELBOW
WELL
SEAL
WELL POINT
INSTALLATION
1-1/2” DISCHARGE PORT
1-1/2”
GALVANIZED
PIPE
WELL POINT
1-1/2” PVC
ELBOW
MULTIPLE WELL
POINT INSTALLATION
CHECK
VALVE
TO
PUMP
TO SP
RINKL
ER SY
STEM
PRIMING PORT
1-1/2” SUCTION PORT
DRAIN PLUG
1-1/2” PVC
ELBOW
Figure 4
PRIMING PORT
1-1/2" SUCTION PORT
DRAIN PLUG
1-1/2" DISCHARGE PORT
Figure 5
B. Discharge port Connections (Figure 5)
Step 1:
Thread male adapter or pipe nipple into discharge port
on top of pump. (Use PTFE tape on thread)
Step 2:
Connect pipe between the sprinkler manifold and
the pump discharge. Discharge pipe size should
increase with long pipe runs. Discharge pipe size
may equal discharge port size for distances up to
100'. Increase discharge pipe size by one size for
distances of 100' to 300'. For 300' to 600', increase
pipe size by two sizes. This will reduce pressure
loss caused by friction.
Step 3:
Tighten all threaded pipe connections with pipe wrench
until snug. Do not over tighten.