Mounting the Units

 

• Mount the TS-RA1, and/or TS-RK units through the four (4) 

mounting holes provided in the case under the front cover.

4.22"

107 mm

Internal View (Cover Removed)

EXT

ALARM

CON.

110 VAC 

(NEUT)

(LINE)

110 VAC 

GND

(4) Holes for 

#8-32 Mounting Screws

4.22"

107 mm

G1

(Flasher)

Figure 2: TS-RA1 Mounting Details 

4.22"

107 mm

4.22"

107 mm

Internal View (Cover Removed)

(4) Holes For 

#8-32 Mounting Screws

NEUTRAL

1-2

LATCH

MODE

ACKN

SWITCH

REMOTE

ALARM

SIGNAL

FLASH

SHUNT

FLASH

DRIVE

OUTPUT
OUTPUT

RETURN

GROUND

1-7

1-9

1-8

1-6

1-5

1-4

1-3

F1

LINE

1-1

2-1

2-2
2-3

2-4

Figure 3: TS-RK Mounting Details

•   Mount the TS-RA2 unit through the two (2) mounting 

holes provided.

0.25 DIA (6.4 MM)

  (2) HOLES

5.0"

127 mm

Figure 4: TS-RA2 Mounting Details

Wiring the Units

Materials Required

•   Wire: 18 to 14 AWG, 300 Volt, type TFFN, THWN, 

or THHN (Note: THHN is not available in 18 AWG). 

Recommended insulation colors are black, white, green, 

and blue.

•   Conduit: 1/2 inch, or 3/4 inch (the TS-RA2 has a 1/2 inch 

NPT for threaded conduit / fitting).

•   Fittings: for conduit used, and conduit hold-down clamps.
•   Sealant: waterproof conduit, fittings, fitting threads, and 

conduit accesses to the building.

•   Fasteners: appropriate for the wall construction involved.
Refer to the schematics on the following page for 

connection information.

Summary of Contents for TS-RA1

Page 1: ...rms Installation Guide franklinfueling com 3760 Marsh Rd Madison WI 53718 USA Tel 1 608 838 8786 Fax 1 608 838 6433 Tel USA Canada 1 800 225 9787 Tel UK 44 0 1473 243300 Tel Mex 001 800 738 7610 Tel D...

Page 2: ...s associated systems When no other regulations apply follow NFPA codes 30 30A and 70 from the National Fire Protection Association Failure to follow these codes could result in severe injury death ser...

Page 3: ...Overfill Alarm and Alarm Acknowledge unit enclosures must be less than 1000 feet away from the 120 VAC electrical power source panel The TS RA1 or TS RA2 Tank Overfill Alarm unit should be mounted ne...

Page 4: ...NE 1 1 2 1 2 2 2 3 2 4 Figure 3 TS RK Mounting Details Mount the TS RA2 unit through the two 2 mounting holes provided 0 25 DIA 6 4 MM 2 HOLES 5 0 127 mm Figure 4 TS RA2 Mounting Details Wiring the Un...

Page 5: ...8 OUTPUT 1 9 OUTPUT RETURN 1 3 GROUND 1 4 1 5 REMOTE ALARM SIGNAL ACKN SWITCH LATCH MODE Console Relay Outputs NC1 C1 NO1 NC2 C2 NO2 TS RA1 TS RK 110 VAC LINE 110 VAC NEUT GND EXT ALARM CON To 110 VA...

Page 6: ...AUD L SW1 1 2 3 4 O N 2AG 3A Fuse Console Relay Outputs TS RK and TS RA2 Wiring Schematic TS RA2 SW1 Switch Position Settings factory settings are shown in bold italic Sound Ouput Level Position 1 Ton...

Page 7: ...de you select refers to the correct High High or High product threshold You can confirm the units in which the High and High High thresholds are measured under Fuel Management Systems High Product Lim...

Page 8: ...FFS 2018 000 1027 r7...

Reviews: