background image

8

Fault Indicators

When an error has occurred during the weld cycle that will have an effect on 

the success of the joint, the red warning LED on the right side of the display 

will light up. Also one of the “weld progress” lights will light up at the same time 

to show what type of fault has occurred. 

Error 

LED

Fault 

Indicated

Meaning

Solution

1

Power supply 

failure during 

weld

The power supply was 

off at sometime during 

the weld 

• 

Check and repair power supply

• 

Check plug connection

• 

Check cables are not damaged or 

broken

• 

Re-weld fitting only after it is allowed 

to cool to ambient temperature

2

Stop button 

pressed 

during weld

Stop button was 

pressed

• 

Re-weld fitting only after it is allowed 

to cool to ambient temperature

3

Power supply 

out of limits

Supply frequency not 

between 40 and 70 

Hz, or Voltage not 

between 194 & 264V

• 

Check and rectify generator output

• 

Check mains supply

• 

Make sure supply is to required 

specification

4

Ambient 

temperature 

out of range

Temperature of the 

EF1 is not between 

-15° C (5º F) and  

+45° C (113º F)

• 

Allow EF1 and fitting to cool in the 

shade

• 

Wait for ambient temperature to return 

to range

5

No output 

current  

(open circuit)

Loose connection to 

terminal pin

Loose contact in the 

welding circuit

Faulty fitting

Start button not 

depressed for long 

enough

• 

Make sure connectors are pushed 

firmly on to terminal pins

• 

Check welding cable connection and 

continuity

• 

Move generator closer and use shorter 

extension  cord

• 

Replace fitting

• 

See operating sequence, step 5

6

Low output 

current

Resistance value of 

fitting is too high

Too many fittings 

connected in series 

(Primary mode only)

Input voltage too low

• 

Use only UPP™ electrofusion fittings 

and correct welding cable

• 

Check resistance codes on fittings - do 

not exceed a sum total of 10

• 

Check supply voltage

• 

Check extension leads being used are 

to specification

7

High output 

current

Regulation error in 

electronics

• 

Switch off machine and switch on 

again after 10 seconds. 

• 

Ensure welder is within temperature 

range

• 

If problem persists, return EF1 to 

supplier

The EF1 can be reset after a fault has been remedied by pressing and holding 

the START / STOP button for 3 seconds.

Summary of Contents for EF1-230V

Page 1: ...nd Held Welder Operating Manual For use Only with UPP Electrofusion Components Franklin Fueling Systems 3760 Marsh Rd Madison WI 53718 USA Tel 1 608 838 8786 800 225 9787 Fax 1 608 838 6433 www franklinfueling com ...

Page 2: ...he welder from getting wet Always check that the power source is within the parameters shown below before using the EF1 Never lift or pull the machine by its power cable or the welding cables Never disconnect welding cables by pulling the cable always pull off the connectors Never re weld a fitting that is still warm Serious fire or burn damage can occur and hot material may be ejected from the we...

Page 3: ...ed with A quality 230 VAC 50Hz power supply with maximum tolerance of 15 A quality generator capable of supplying a minimum of 2 8kW 3 5 kVA Note that an earth spike grounding rod must be used with generators If used with a 110v to 230v step up transformer follow these specifications Safety Isolating transformer 3 3kVA minimum Auto transformer 3 3kVa minimum Extension Cords Cables Extension cables...

Page 4: ...fittings This is done by using color coded welding leads as shown below Type of Fitting Welding Cable Colour Size of Welding Pin mm Current amps Weld Time 20C Seconds Primary and Gemini Secondary fittings Red 4 4 184 Secondary Green 2 5 80 Fusion Chamber White 2 3 7 360 Large Diameter 10amp Black 2 10 365 The EF1 can be used in ambient temperatures between 15 C 5ºF and 45 C 113ºF Only personnel fu...

Page 5: ...energy required to weld correctly It must therefore be allowed to reach ambient temperature before use and must be at the same temperature as the fitting to be welded The temperature sensor is located adjacent to the power cable entry gland The EF1 works on standard alternating current and either a mains connection or a generator can be used Generators must have a rated output of at least 3 5kVA a...

Page 6: ...the orange START button until first weld light illuminates The first weld light comes on then successive LEDs light up until green 100 LED is lit showing weld is complete 6 Disconnect welding lead from fitting The 100 LED and Power LED remains on 7 ALWAYS Reset for next weld by holding START button for 3 seconds All LEDs will light in sequence then the green power LED remains on Other Important Ti...

Page 7: ...or no marking may NOT be welded in series Maintenance There are no user serviceable parts inside the EF1 welding unit Damaged or defective products should be returned to an approved service agent for repair or calibration Welding unit and cables should be checked for damage or defects and parts repaired or replaced prior to each use The welding unit can be cleaned using a soft brush or cloth After...

Page 8: ...erature of the EF1 is not between 15 C 5ºF and 45 C 113ºF Allow EF1 and fitting to cool in the shade Wait for ambient temperature to return to range 5 No output current open circuit Loose connection to terminal pin Loose contact in the welding circuit Faulty fitting Start button not depressed for long enough Make sure connectors are pushed firmly on to terminal pins Check welding cable connection ...

Page 9: ...tion of Conformity This welding unit has been designed to comply with the harmonised standards under New Approach directives and has been CE Marked accordingly The applicable standards are 2004 108 EC Electromagnetic compatibility 2006 95 EC Low voltage equipment 98 37 EC Machinery safety 94 62 EC Packaging and packaging waste 2008 34 EC Waste electrical and electronic equipment 2008 35 EC Restric...

Page 10: ...10 Page intentionally blank ...

Page 11: ...11 Page intentionally blank ...

Page 12: ... FFS 2014 408001010 Rev4 ...