Franklin Home Power User Manual
Date
August 10, 2021
Doc. No.
FD21081001
Revision
V01
© 2021. FranklinWH Technologies Co., Ltd.
Page 18 Total 31
type
EPO
EPO connection, NC type
Reserved
DI1
Generator alarm, NO type
Reserved
CAN IN
Communication between aGate and
aPoewers
Loop-in wiring system.
If the loop is broken (2 CAN
cables are broken), the power
system will be off. Only 1 CAN
cable is broken, the system
works well.
CAN OUT
VCC IN
20VDC from aPower
Loop-in wiring system
If the loop is broken (VCC
in/VCC out cables are all
broken), the system will power
off when the grid/solar is off.
Otherwise, the system will work
well.
VCC OUT
DI2
NO type
Reserved
DI3
NO type
Reserved
DI4
NO type
Reserved
Eth1
100M, Ethernet ports to the home
gateway or VPP networks
Plug and play
Eth2
SIM card
Support the U.S. and Canadian
standards GSM, WCDMA, CDMA EVDO,
CDMA2000, LTE (FDD), LTE (TDD),
Mobile network, cloud access
(alternate channel)
CT5,CT6, (J7)
Grid CT connection
4G/WIFI
4G/WIFI connection
SMART RELAY
Connect to smart circuit relay in
aGate
SOLAR RELAY
Connect to the solar board in
aGate
RS485
Connect to AC meter in aGate
3.6 aGate optional
1) Optional generator circuit relay
The generator circuit connection is blanked by default. The
Figure Optional generator circuit relay