4.2 aGate datasheet
Table aGate datasheet
PERFORMANCE SPECIFICATION
COMPLIANCE INFORMATION
AC Voltage (Nominal)
120/240VAC
Certificate
UL1741 PCS, UL67
1
,
UL869A
1
, UL916
Feed-in Phase
Split, L1/L2/N/PE
Emission
FCC Part 15 Class B
2
Grid Frequency
60Hz
MECHANICAL SPECIFICATION
Overcurrent Protection Device
200A maximum
Dimensions (H x W x D)
31.5in x 21.7in x 6.3in
(800mm x 550mm x 160mm)
Maximum Input Short Circuit Current
10kA
Weight
48lbs. (22kg)
Overvoltage Category
Category IV
Mounting
Wall mount or
Semi-flush mount
AC Meter
Ac/-1%
ENVIRONMENTAL SPECIFICATION
Backup Transition
<16ms
Operation Temperature Range
-4°Fto 122°F(-
20℃to 50℃)
Connectivity
Ethernet, WIFI, 4G
Operating Humidity (RH)
Up to 95%RH,
no condensing
Work Modes
Self-Consumption
Load Shifting
Backup Standby
Emergency Backup
Maximum Elevation
9843 feet (3000m)
User Interface
FranklinWH APP
Environment
Indoor and outdoor rated
Solar Input Protection Device
80A Max.
Enclosure Type
Type 3R
Genset Overcurrent Protection Device
200A Max. (Optional)
Smart Circuit Protection Device
(Optional)
1*80A Max.@240V
2*50A Max.@120V
Scalability
Up to 15 aPowers
Warranty
12 years