8. MECHANICAL
Versatile mounting ‘T’ pieces slide into slot at the bottom of the Bar.
Two mounting slides for Bars up to 1 m, plus extra mounting brackets for each additional 500 mm.
9. MAINTENANCE
Turn off power supply to the Bar before doing any installation or maintenance work.
Cleaning is the only maintenance required. Dirt around the emitters will reduce efficiency and result in
unsatisfactory performance.
Our Fraser cleaning kit (Part Number 81220) is ideal for use, alternatively a toothbrush or nail brush can be used.
Do not use a wire brush as this could damage the Bar.
The Bar can be washed with soapy water or IPA, but it must be dry around the emitters before turning the power on.
Please note, when handling and cleaning, that the
emitter pins are sharp and care is needed!
The emitter pins are shockless - there is a large resistor below each emitter reducing the current to a shockless
level. However please note that DC current can transfer charge to a body if it is touching or close to an emitter
for a longer period. This could give a shock when discharging.
The emitters on NEOS 30 OEM should be replaced every two years. Please use the emitter key supplied with
the Bar to remove/replace.