background image

 ICsystems rev0402

12

IC400/500 SERIES INSTALLATION

Note: In a three-way system (IC500) master station A has transmit priority

over master station B and the remote station.

Note: Mounting hardware is not included, number 10 hardware is

recommended.

Pre-Installation

1. Measure and mark station box locations for panel opening and four screw

holes. Refer to Figure 7 for layout and dimensions.

2. Drill four mounting holes at each station box location for mounting hardware.

3. Cut out panel opening at each station location.

Note: Pre-installed apparatus wiring can be used. The intercom connections

are one-to-one. The yellow wire is shield.

4. Install the cable (with 3-pin connector) between remote and master station

box locations. Refer to Figure 8 or 9 for wiring details.

5. For three-way system (IC500) install the cable (with 5-pin connector)  between

master stations A and B box locations. Refer to Figure 9 for wiring details.

Install Remote Station

1. Place station box in position and secure with four screws.

2. Connect station box 3-pin Molex connector to cable connector.

Install Master Station(s)

1. Place station box(es) in position and secure with four screws.

2. Connect station box 3-pin Molex connector to cable connector.

3. For three-way system (IC500) connect station box 5-pin Molex connector to

cable connector.

4. Connect black wire to ground.

5. Connect red fused wire to +12 VDC.

6. For three-way system repeat steps 3 through 5 at master station B.

Summary of Contents for IC100 Series

Page 1: ...UE VEHICLE MODEL IC100 SERIES SURFACE MOUNT MODELS IC200 IC300 SERIES FLUSH MOUNT MODLES IC400 IC500 SERIES FIRE RESEARCH CORPORATION fireresearch com 26 Southern Blvd Nesconset NY11767 TEL 631 724 8888 FAX 631 360 9727 TOLL FREE 1 800 645 0074 ...

Page 2: ...00 SERIES INSTALLATION 12 Pre Installation 12 Install Remote Station 12 Install Master Station s 12 OPERATION 16 Basic Two Way System 16 Basic Three Way System 16 System Options 16 Operational Check 17 List of Tables Table 1 Intercom Specifications 3 List of Figures Figure 1 IC100 Mounting Dimensions 6 Figure 2 IC100 Wiring 7 Figure 3 IC 200 300 Adjustable Mount 9 Figure 4 IC200 300 Mounting Dimen...

Page 3: ... S E I R E S 0 0 5 0 0 4 C I S E I R E S 0 0 5 0 0 4 C I Y L P P U S Y L P P U S Y L P P U S Y L P P U S Y L P P U S E G A T L O V C D V 2 1 C D V 2 1 C D V 2 1 T U P T U O T U P T U O T U P T U O T U P T U O T U P T U O R E W O P S T T A W 8 S T T A W 6 1 S T T A W 6 1 E S U F E S U F E S U F E S U F E S U F P M A 3 D E D N E M O C E R P M A 3 W O L B W O L S L D M 5 2 1 X 5 2 P M A 3 W O L B W O...

Page 4: ...ess background noise is picked up by the hands free remote station due to vibration mounting it on a rubber pad can help reduce noise Ensure a good ground connection Isolate the intercom ground wire from other grounds that can be noisy strobes radios priming motors etc Make interconnecting cable runs as short as possible Secure excess intercom cable in a figure 8 pattern The foot switch option req...

Page 5: ... Install Remote Station 1 Place station box in position with mounting post through the holes and secure with two nuts The nuts should be hand tight plus 1 4 turn 2 Connect station box four wires to cable Refer to Figure 2 for wiring details Install Master Station 1 Place station box in position with mounting post through the holes and secure with two nuts The nuts should be hand tight plus 1 4 tur...

Page 6: ...ICsystems rev0402 6 Figure 1 IC100 Mounting Dimensions Two 3 4 holes are needed Remote Station Master Station Two 3 4 holes are needed 4 2 5 8 3 4 3 4 2 1 2 5 1 4 4 1 4 2 1 2 1 5 8 3 1 4 7 8 7 8 ...

Page 7: ...C GND Red Black Yellow White Black White Yellow Red Note It is recordmended that a 3 AMP fuse be installed between the master station box and the 12 VDC power source Red Black A one to one cable connects the two stations Black to Black White to White Red to Red Yellow to Yellow ...

Page 8: ...box locations Refer to Figure 5 or 6 for wiring details 4 For three way system IC300 install the cable with 5 pin connector between master stations A and B box locations Refer to Figure 6 for wiring details Install Remote Station 1 Place mounting bracket in position and secure with four screws 2 If bracket was removed from box place remote station box in position and install rubber bushings and mo...

Page 9: ...les Figure 4 IC200 300 Mounting Dimensions Drill the holes for 1 4 inch mounting hardware 4 1 4 3 4 3 4 3 Figure 3 IC 200 300 Adjustable Mount Station Box Adjustment Knob Mounting Bracket Rubber Bushing Adjustable Provide enough slack in the cable s for the station box to be adjusted as needed ...

Page 10: ...ICsystems rev0402 10 To Remote Station Figure 5 IC200 Wiring Remote Station Master Station GND 12 VDC Fuse 3 AMP 3 Pin Molex Connector Wiring White Yellow Black ...

Page 11: ...on To Master Station B Figure 6 IC300 Wiring Remote Station Fuse 3 AMP Master Station B GND 12 VDC Master Station A GND 12 VDC Fuse 3 AMP 3 Pin Molex Connector Wiring White Yellow Black 5 Pin Molex Connector Wiring Red Yellow White Black ...

Page 12: ...e is shield 4 Install the cable with 3 pin connector between remote and master station box locations Refer to Figure 8 or 9 for wiring details 5 For three way system IC500 install the cable with 5 pin connector between master stations A and B box locations Refer to Figure 9 for wiring details Install Remote Station 1 Place station box in position and secure with four screws 2 Connect station box 3...

Page 13: ...ng Dimensions Master Station Cutout and Mounting Holes Remote Station Cutout and Mounting Holes Suggested Panel Opening 5 1 8 H x 5 1 8 W Suggested Panel Opening 6 3 8 H x 5 1 8 W Drill the holes for number 10 mounting hardware 6 3 4 5 1 2 5 1 2 5 ...

Page 14: ...ICsystems rev0402 14 Figure 8 IC400 Wiring To Remote Station Master Station GND 12 VDC Fuse 3 AMP Remote Station 3 Pin Molex Connector Wiring White Yellow Black ...

Page 15: ...Wiring To Master Station B To Remote Station Master Station B GND 12 VDC Fuse 3 AMP Remote Station Master Station A GND 12 VDC Fuse 3 AMP 5 Pin Molex Connector Wiring Red Yellow White Black 3 Pin Molex Connector Wiring White Yellow Black ...

Page 16: ...tion B and the remote station System Options Handheld Microphone ICX01 Option This option is for installations in high noise areas The microphone plugs into a receptacle on the station box The system can be keyed to transmit with the microphone switch or the PTT button on the station box Foot Switch Option This option requires the installation of a single pole single throw foot switch not supplied...

Page 17: ...ice is heard at remote station and master station B 4 Release PTT button 5 Press and hold PTT button on master station B box 6 Speak into the box and adjust volume knob for transmit and receive level Result Voice is heard at remote station and master station A 7 Release PTT button 8 Speak into remote station box Result Voice is heard at master station A and master station B Handheld Microphone and...