Specifications
The PRO-S is available in various models. Each model is programmed to interface
with specific engines. All models provide the same functions, push button controls,
and digital readout for the management of pump discharge pressure. (Refer to Table 1
for detailed specifications.)
Table 1. PRO-S Specifications
Note 1: 24 VDC Optional
PRO-S 1
PRO-S 2
PRO-S 3
PRO-S 4
PRO-S 5 PRO-S 6 PRO-S 7 PRO-S 8 PRO-S 10
ENGINE
Cummins
(IS Series)
Detroit Diesel
(Series 50 and
60)
Non-
Electronic
Navistar and
Detroit Diesel
(Series 40)
Caterpillar
Ford
Mack
Scania
Mercedes
SUPPLY
VOLTAGE
(See Note 1)
12 VDC
12 VDC
12 VDC
12 VDC
12 VDC
12 VDC 12 VDC 12 VDC
12 VDC
SUPPLY
CURRENT
1.0 AMP
1.0 AMP
3.0 AMP
1.0 AMP
1.0 AMP 1.0 AMP 1.0 AMP 1.0 AMP 1.0 AMP
RESPONSE
(Idle to full
governed speed)
5 SEC
5 SEC
30 SEC
5 SEC
5 SEC
5 SEC
5 SEC
5 SEC
5 SEC
RECOVERY
(After open or
close of valve)
1.5 SEC
1.5 SEC
1.5 SEC
1.5 SEC
1.5 SEC 1.5 SEC 1.5 SEC 1.5 SEC
1.5 SEC
RPM
CALIBRATION
None
None
Manual
None
None
Manual
None
Manual
None
DATALINK
PROTOCOL
J1587
J1587
J1587
J1587
J1587
J1587