background image

Document Number

XM-LGT1PMEX-R5F

LGTR5F-Rev150518

FIRE RESEARCH CORPORATION

26 Southern Blvd., Nesconset, NY  11767

TEL  631.724.8888  FAX  631.360.9727

TOLL  FREE  1.800.645.0074

www.fireresearch.com

INSTALL LAMPHEAD ON TELESCOPIC POLE

Refer to the General Lighting manual or lamphead and model specific sheets for safety, maintenance, and installation instructions.
Lampheads and telescopic poles are shipped apart and need to be assembled.

Note:

 The 512 telescopic pole must be installed before the lamphead is attached if the small diameter hole is used. Refer to template 

drawing for 512 Thru-The-Roof mount.

1.  Place the lamphead and the pole on a flat surface.
2.  Connect the lamphead wires to the pole wires.
 

a. Ensure that 3/8 inch of bare conductor shows at the end of 

each wire.

 

b. Insert the wires in the butt connectors and crimp.

3.  Ensure the crimps are tight. (Test by lightly tugging on the wires.)

4.  Loop the excess wire in a zig-zag fashion to take up the slack.
5.  Slide the lamphead onto the pole tucking the wires into the pole.

Note:

 Ensure that the wires are not caught and 

squeezed by the lip of the pole. If this happens the 

wire insulation may be cut and short the wire to 

the pole.

Note:

 Dimension A should be less than 0.015" (the thickness of a folded piece of 

paper). If A is larger, a wire is probably caught. Disassemble and check for 

wire insulation damage. If there is no damage, reassemble.

6.  Apply thread lock and tighten the set screws to secure the lamphead 

on the pole. (A medium strength locking compound like Loctite blue 

is recommended.)

Apply thread lock and tighten the set screws.

A

SPECTRA MAX-S WIRING,

LAMPHEAD INSTALLATION AND

MOUNTING BRACKET TEMPLATES

SPECTRA Max-S

12/24 V DC

Connect the RED wire to POWER.
Connect the BLACK wire to GROUND.
Connect the ORANGE wire to  POWER.
Connect the BLACK wire to GROUND.

120/240 V AC  

(without Switch option)

Connect the GREEN wire to chassis GROUND.
Connect the WHITE wire to RETURN.
Connect the RED wire to POWER.
Connect the WHITE wire to RETURN.
Connect the BLACK wire to POWER.

{

}

SPOT

{

}

FLOOD

{

}

FLOOD

{

}

SPOT

-ON

(with Switch option)

Black

Black

White

White

Silver Braid

Green

Red

White

Black

White

Green

(

without

 Switch option)

DC powered light will only have four wires: 

RED + BLACK and BLACK

R

W

B W

G

R

W

B W

G

MAINTENANCE

Use a clean soft cloth, mild soap, and water to clean the lens. 

NOTE:

 FRC led lampheads use Lexan lenses and cleaning with 

abrasive materials, solvents, or most chemical cleaners can 

cause lens surface degradation and reduced performance of 

the light. 

Some chemicals will cause the lens to become 

brittle and prone to cracking.

Reviews: