WLA300 Rev170606
20
OPERATION
No operator input is required for the TankVisionPro to be operational. When power
is on, the display is operating. The signal from the pressure sensor is processed and
the volume of liquid in the tank shows on the display.
Note:
Calibrating the TankVisionPro display to the tank is required before
operations. (Refer to Calibration section.)
Primary Display Module
All LEDs are on when the tank is full. Each LED goes off starting at the top and
working down as the liquid in the tank decreases.
The bottom 3 LEDs flash when the tank is less than 1/4 full.
(For the WLA400 Series, the visual warning indicator signal is synchronized
with the flashing LED on the display.)
All LEDs rapidly down-chase when the tank is almost empty.
Options
Programmable LED Display
LED Indicator lights can be programmed to be Red for all 9/10 rows, or one of
the patterns shown on pages 27-29.
12 Pin Connector with Additional Features:
Visual warning output. (Active ground; Maximum 150mA)
Silence button input for audio warning only. (Active ground)
Separate Valve control output. (Active ground; Maximum 150mA)
Separate ground connection for the level sensor
Remote Display Module
The remote display repeats exactly what is shown on the master display.
Cab Miniature Display
All 5 LEDs is on when the tank is full. The LEDs will show full, 3/4, 1/2, 1/4,
and empty tank.
MaxVision LED Display
The LED display repeats exactly what is shown on the master display.
Summary of Contents for TankVisionPro WLA300
Page 43: ...WLA300 Rev170606 43 NOTES ...
Page 44: ...WLA300 Rev170606 44 ...