Warning and Control Level Adjustment
Code 21
To set the Audio warning level. Default—1/4 (25%)
Code 22
To set the Visual warning level. Default—1/4 (25%)
Code 23
To s e t t h e "
Ta n k F u l l "
a u d i o s i g n a l l e v e l .
Default—disabled.
Code 24
To set the Valve control signal "
Low
" activation level.
Default— 1/2 (50%)
Code 25
To set the Valve control signal "
Full
" deactivation level.
Default —7/8 (95%)
Code 26
To set the level for Audio warning to be turned off (or disabled).
Default —1/4 (25%)
Code 27
To set the level for Visual warning to be turned off.
Default —1/4 (25%)
Code 28
To set the delay time in seconds before the Audio warning is activated.
Default —1 second (
NOTE
: each LED delays the Audio warning
activation by 1 second. This is adjustable from 1 to 7 seconds. )
1. Enable the data entry by holding the magnet at
C 2
for 5 seconds. This sets the
desired level for either Warnings or Valve Control setting activation.
2. Wait five seconds.
3. Save the new setting by holding the magnet at
C 2
for 5 seconds.
Note
: If the WL300 is set with code 24 and 25, the buzzer output will work
as a valve controller.
Figure 11. Diagnostics - Warnings