Brightness Adjustment
Code 31
Day time brightness. Default—Brightness Level - 8
Code 32
Night time brightness. Default—Brightness Level - 2
1.
Every magnet swipe at
C 1
will incrementally increase/decrease the
brightness for 10 various levels.
2.
Starting from the lowest level, repeat the process from number 1.
3.
Enable the data entry by holding the magnet at
C 2
for 5 seconds.
4.
Adjust the brightness to the desired level.
5.
Save the new setting by holding the magnet at
C 2
for 5 seconds.
Primary and Remote Synchronization
If the level pressure sensor is detected, (0.3V or more) the unit will work as a
Primary display. Any remote unit including Water, Foam A, or Foam B, and MaxVision,
that is connected via CAN bus will be synchronized with following settings:
• Tank level calibration
• Display Pattern
• Warning and control activation levels
NOTE
: Brightness will remain as adjusted locally in the remote display unit.