WLA300 Rev170606
37
Remote Light Driver
Notes:
Connect a wire from the primary or a remote display module pin 6 to the remote
light driver pin 2 (this is the input signal to the remote driver). If there is no signal on
pin 2 the lights remain off.
Connect power to pin 3 and to pin 8, this is power for the remote driver and the
remote lights. It is recommended that pin 3 and pin 8 be tied together. The maximum
current is 20 AMPS @ 12VDC (10 AMPS @ 24 VDC).
1
4
5
8
Figure 16. Remote Light Driver Wiring
Light Driver Connector
Pin Signal Description
1
Ground
2
Signal Input
3* Remote Light Power
4
1/4 Tank Output
5
1/2 Tank Output
6
3/4 Tank Output
7
Full Tank Output
8* Remote Light Power
Remote Light
Driver
*
Light Power
(12 VDC 20 A)
(24 VDC 10 A)
Use 16 AWG Wire
GND
Full Tank
Typical Remote
Light Stack
(four 60 watt lights)
Ground
Input From
Display Module Pin 6
1/2 Tank
3/4 Tank
1/4 Tank
Note:
If there is no signal on pin 2
(input from a display module) the
lights remain off.
Summary of Contents for TankVisionPro WLA300
Page 43: ...WLA300 Rev170606 43 NOTES ...
Page 44: ...WLA300 Rev170606 44 ...