TH4C Installation Guide
p. 40
TH4C Advanced Configuration
© Safe Fleet | May 2019 | All rights reserved
Document Number: XE-SNB2-TH4CPM-R0A
ITEM
DESCRIPTION
VALUE [DEFAULT]
Axis
X - forward/back axis
Y - left/Right axis
Z - vertical axis
Vector - combination of X and Y axes (to capture driver behavior incidents)
Accident - combination of X and Y axes (higher threshold settings, to
capture vehicle accidents)
n/a
Current
The current (live) values measured by the G Sensor (display only)
n/a
Threshold
Set from 0G to 6.0G. This value configures the threshold level. Any value
beyond the threshold triggers the output, as configured in the Output field.
X = [+/- 2.00]
Y = [+/- 2.00]
Z = [+/- 3.00]
V = [+ 3.00]
A = [+ 5.00]
Output
If the specified G Sensor threshold value is exceeded, the DVR triggers
the selected output (DVR log entry, Signal, or Alarm).
[OFF], Log, S01-S10,
ALM1-ALM4
Peak
Use the observed peak values to refine threshold settings.
Peak values reflect detected G Sensor levels for axis, Vector, and
Accident activity.
n/a
Menu Options
FRC recommends the default G-Sensor settings for large apparatus movement detection.
Smaller vehicles may require lower thresholds - some experimentation may be necessary to define the optimal
configuration for each vehicle type. If thresholds are set too low, they may generate many alarms.
TIP: G Sensor settings recommendation
i
Summary of Contents for TH4C
Page 2: ......