ADS-B FDL-DB Dual Band Series
Installation Manual
Document No. 88552 Rev A
5-16
FFS Copyright © 2020 All rights reserved.
Table 18: Network Server Port Connection Settings
Setting
Interface
Description
ip
Network
Server
TCP
or
UDP
protocol selection
local_port
Network
Server
TCP
or
UDP
Server port.
remote_addr
Network
Server
UDP
UDP
Client IP address
remote_addr =
0.0.0.0
Send output to IP address/port of most recently received
client
remote_addr = 255.255.255.255
Send output to Broadcast IP
remote_addr = Other
Send output to remote_addr:remote_port
remote_port
Network
Server
UDP
UDP
Client IP port
5.1.1.6 Network Server Port Input Configuration Details
The following table defines the network server port input data formats:
Table 19: Network Server Port Input Configuration Settings
Setting
Interface
Description
cntrl enable
Control
Input
Squawk Code, IDENT, Call Sign, and mode (standby/alt
inhibit). Enables display control from a GMX-200, or other
displays using the GDL/FDL protocol. The corresponding
network server output port must be configured to Traffic-
Alert to enable display control input.
(2) (6)
5.1.1.7 Network Server Port Functionality Configuration Details
The following table defines the network server port output data formats:
Table 20: Network Server Port Output Configuration Settings
Setting
Interface
Description
Traffic-Alert
Display
Output
Ownship data, traffic reports, and FIS-B data. Format for
the Aspen, GMX-200, Chelton displays, or other displays
using the GDL/FDL protocol. The corresponding network
port input can be configured to
“cntrl enable” to enable
display control input.