background image

Quick Set-up Guide

This is intended as a reference guide, please 

read entire User Manual prior to use.

Assembly Layout

Breast Funnel

Breast Funnel

Barrier

Valve

Valve Base

Valve Base

Cup

Cup

See reverse side or User Manual for 

pump 

Connection Diagrams

Must boil these parts for 10 

minutes before first use only for 

secure fit between parts.

Ensure all parts are dry prior to use. Do not steam sterilize or use 

abrasives on any Freemie components. Steam may damage parts and 

cause these parts to not fit securely.

Do not boil or steam 

these parts:

Clean parts with hot soapy water and 

rinse thoroughly after each use.
Leave parts disassembled between use.

Incorrect assembly of the milk backflow barrier will cause low 

or no suction.

Step 1:

 Place Barrier onto funnel 

mounting ridge and against 

cone surface.

Step 2:

 Align Valve Base 

with Barrier and Funnel and 

push together.

Step 3:

 Press Breast Funnel and 

Valve Base firmly together.

Step 4:

 Press Valve onto 

valve base.

Ensure all connections are secure and tight to prevent loss of suction.

Replace valves approximately every 3 months

Funnel Tubing Port

Cup Arrow

Step 5:

 Align cup arrow with funnel tubing port, seat cup rim into the outer 

ring of the funnel, and snap together to secure the assembly.

Practice pouring water from Freemie Cups into a 

storage bottle or bag before trying with pumped 

milk to help ensure successful transfers.

Bra fit is critical for proper use.

Before choosing a bra, pump with the Freemie using your hands to hold 

the Cups in place.
To achieve the same pressure and sensation with the Freemie Cups in 

your bra, it may be necessary to adjust your bra or try different bras to 

find the best fit for you. A sports bra or stretchy nursing bra works well for 

some women.
Freemie Cups can be used discreetly with proper wardrobe planning. 

Loose clothing with easy access and scarves will be most discreet. Before 

first use in public, put water in the Cups and practice placement and 

removal of the Cups in your bra. This exercise will help in determining 

wardrobe requirements.

Place Freemie Cup inside your 

bra with tubing facing upright 

in the 12 o'clock position.

Tubing in 

12 o'clock 

position.

Freemie Breast Funnel should be centered over 

the nipple.

Pump with Freemie Cups in an upright position, such as 

sitting or standing

You may pump in any of these positions. The position of the cups 

relative to the horizon is important, as your milk needs to flow 

downhill in the funnel.

Optimal

Okay

May cause milk to spill

Incorrect

Note: Depending on the shape and orientation of your breasts, you may be able to 

comfortably pump in a wide variety of positions.

• Turn off pump, remove tubing from Freemie Cups.
• Carefully remove Freemie Cups from your bra.

Handle cups with care.

 Milk pours out from pour spout. Placement at any 

other position may cause milk to flow into the tubing or leak out of cups.
Transfer milk to storage container or bottle after pumping. Pour quickly 

with breast funnel up.
Handwash all components that come into contact with breast milk in hot 

soapy water, then rinse thoroughly. 
Leave parts disassembled until ready for next use.

Closed System Collection Cups

3.

 

Before using Freemie

®

4.

 

Freemie

® 

position and placement

5.

 

Transfer milk from Freemie

® 

Cups

1.

 

Preparing for first use

2.

 

Assemble Freemie

® 

Cups

May cause milk to spill

Tubing

Y Connector

Barrier

Valve

Hand wash valve in 

hot, soapy water. 

Rinse thoroughly.

Reviews: