Quick Set-up Guide
This is intended as a reference guide, please
read entire User Manual prior to use.
Assembly Layout
Breast Funnel
Breast Funnel
Barrier
Valve
Valve Base
Valve Base
Cup
Cup
See reverse side or User Manual for
pump
Connection Diagrams
Must boil these parts for 10
minutes before first use only for
secure fit between parts.
Ensure all parts are dry prior to use. Do not steam sterilize or use
abrasives on any Freemie components. Steam may damage parts and
cause these parts to not fit securely.
Do not boil or steam
these parts:
Clean parts with hot soapy water and
rinse thoroughly after each use.
Leave parts disassembled between use.
Incorrect assembly of the milk backflow barrier will cause low
or no suction.
Step 1:
Place Barrier onto funnel
mounting ridge and against
cone surface.
Step 2:
Align Valve Base
with Barrier and Funnel and
push together.
Step 3:
Press Breast Funnel and
Valve Base firmly together.
Step 4:
Press Valve onto
valve base.
Ensure all connections are secure and tight to prevent loss of suction.
Replace valves approximately every 3 months
Funnel Tubing Port
Cup Arrow
Step 5:
Align cup arrow with funnel tubing port, seat cup rim into the outer
ring of the funnel, and snap together to secure the assembly.
Practice pouring water from Freemie Cups into a
storage bottle or bag before trying with pumped
milk to help ensure successful transfers.
Bra fit is critical for proper use.
Before choosing a bra, pump with the Freemie using your hands to hold
the Cups in place.
To achieve the same pressure and sensation with the Freemie Cups in
your bra, it may be necessary to adjust your bra or try different bras to
find the best fit for you. A sports bra or stretchy nursing bra works well for
some women.
Freemie Cups can be used discreetly with proper wardrobe planning.
Loose clothing with easy access and scarves will be most discreet. Before
first use in public, put water in the Cups and practice placement and
removal of the Cups in your bra. This exercise will help in determining
wardrobe requirements.
Place Freemie Cup inside your
bra with tubing facing upright
in the 12 o'clock position.
Tubing in
12 o'clock
position.
Freemie Breast Funnel should be centered over
the nipple.
Pump with Freemie Cups in an upright position, such as
sitting or standing
You may pump in any of these positions. The position of the cups
relative to the horizon is important, as your milk needs to flow
downhill in the funnel.
Optimal
Okay
May cause milk to spill
Incorrect
Note: Depending on the shape and orientation of your breasts, you may be able to
comfortably pump in a wide variety of positions.
• Turn off pump, remove tubing from Freemie Cups.
• Carefully remove Freemie Cups from your bra.
Handle cups with care.
Milk pours out from pour spout. Placement at any
other position may cause milk to flow into the tubing or leak out of cups.
Transfer milk to storage container or bottle after pumping. Pour quickly
with breast funnel up.
Handwash all components that come into contact with breast milk in hot
soapy water, then rinse thoroughly.
Leave parts disassembled until ready for next use.
Closed System Collection Cups
3.
Before using Freemie
®
4.
Freemie
®
position and placement
5.
Transfer milk from Freemie
®
Cups
1.
Preparing for first use
2.
Assemble Freemie
®
Cups
May cause milk to spill
Tubing
Y Connector
Barrier
Valve
Hand wash valve in
hot, soapy water.
Rinse thoroughly.