Chapter 11 S12XE Clocks and Reset Generator (S12XECRGV1)
MC9S12XE-Family Reference Manual , Rev. 1.19
Freescale Semiconductor
481
The COP time-out period is restarted if one these two conditions is true:
1. Writing a non zero value to CR[2:0] (anytime in special modes, once in all other modes) with
WRTMASK = 0.
or
2. Changing RSBCK bit from “0” to “1”.
Table 11-12. COPCTL Field Descriptions
Field
Description
7
WCOP
Window COP Mode Bit
— When set, a write to the ARMCOP register must occur in the last 25% of the selected
period. A write during the first 75% of the selected period will reset the part. As long as all writes occur during
this window, $55 can be written as often as desired. Once $AA is written after the $55, the time-out logic restarts
and the user must wait until the next window before writing to ARMCOP.
shows the duration of this
window for the seven available COP rates.
0 Normal COP operation
1 Window COP operation
6
RSBCK
COP and RTI Stop in Active BDM Mode Bit
0 Allows the COP and RTI to keep running in Active BDM mode.
1 Stops the COP and RTI counters whenever the part is in Active BDM mode.
5
WRTMASK
Write Mask for WCOP and CR[2:0] Bit
— This write-only bit serves as a mask for the WCOP and CR[2:0] bits
while writing the COPCTL register. It is intended for BDM writing the RSBCK without touching the contents of
WCOP and CR[2:0].
0 Write of WCOP and CR[2:0] has an effect with this write of COPCTL
1 Write of WCOP and CR[2:0] has no effect with this write of COPCTL.
(Does not count for “write once”.)
2–0
CR[2:0]
COP Watchdog Timer Rate Select
— These bits select the COP time-out rate (see
). Writing a
nonzero value to CR[2:0] enables the COP counter and starts the time-out period. A COP counter time-out
causes a system reset. This can be avoided by periodically (before time-out) reinitialize the COP counter via the
ARMCOP register.
While all of the following four conditions are true the CR[2:0], WCOP bits are ignored and the COP operates at
highest time-out period (
2
24
cycles) in normal COP mode (Window COP mode disabled):
1) COP is enabled (CR[2:0] is not 000)
2) BDM mode active
3) RSBCK = 0
4) Operation in emulation or special modes
Table 11-13. COP Watchdog Rates
(1)
CR2
CR1
CR0
OSCCLK
Cycles to Timeout
0
0
0
COP disabled
0
0
1
2
14
0
1
0
2
16
0
1
1
2
18
1
0
0
2
20
1
0
1
2
22
1
1
0
2
23
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:
S12XE
products
in
208
MAPBGA
packages