Chapter 16 Freescale’s Scalable Controller Area Network (S12MSCANV3)
MC9S12XE-Family Reference Manual , Rev. 1.19
634
Freescale Semiconductor
Module Base + 0x00X2
7
6
5
4
3
2
1
0
R
ID14
ID13
ID12
ID11
ID10
ID9
ID8
ID7
W
Reset:
x
x
x
x
x
x
x
x
Figure 16-28. Identifier Register 2 (IDR2) — Extended Identifier Mapping
Table 16-28. IDR2 Register Field Descriptions — Extended
Field
Description
7:0
ID[14:7]
Extended Format Identifier —
The identifiers consist of 29 bits (ID[28:0]) for the extended format. ID28 is the
most significant bit and is transmitted first on the CAN bus during the arbitration procedure. The priority of an
identifier is defined to be highest for the smallest binary number.
Module Base + 0x00X3
7
6
5
4
3
2
1
0
R
ID6
ID5
ID4
ID3
ID2
ID1
ID0
RTR
W
Reset:
x
x
x
x
x
x
x
x
Figure 16-29. Identifier Register 3 (IDR3) — Extended Identifier Mapping
Table 16-29. IDR3 Register Field Descriptions — Extended
Field
Description
7:1
ID[6:0]
Extended Format Identifier —
The identifiers consist of 29 bits (ID[28:0]) for the extended format. ID28 is the
most significant bit and is transmitted first on the CAN bus during the arbitration procedure. The priority of an
identifier is defined to be highest for the smallest binary number.
0
RTR
Remote Transmission Request
— This flag reflects the status of the remote transmission request bit in the
CAN frame. In the case of a receive buffer, it indicates the status of the received frame and supports the
transmission of an answering frame in software. In the case of a transmit buffer, this flag defines the setting of
the RTR bit to be sent.
0 Data frame
1 Remote frame
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:
S12XE
products
in
208
MAPBGA
packages