Chapter 16 Freescale’s Scalable Controller Area Network (S12MSCANV3)
MC9S12XE-Family Reference Manual , Rev. 1.19
636
Freescale Semiconductor
16.3.3.2
Data Segment Registers (DSR0-7)
The eight data segment registers, each with bits DB[7:0], contain the data to be transmitted or received.
The number of bytes to be transmitted or received is determined by the data length code in the
corresponding DLR register.
Module Base + 0x00X2
7
6
5
4
3
2
1
0
R
W
Reset:
x
x
x
x
x
x
x
x
= Unused; always read ‘x’
Figure 16-32. Identifier Register 2 — Standard Mapping
Module Base + 0x00X3
7
6
5
4
3
2
1
0
R
W
Reset:
x
x
x
x
x
x
x
x
= Unused; always read ‘x’
Figure 16-33. Identifier Register 3 — Standard Mapping
Module Base + 0x0004 (DSR0)
0x0005 (DSR1)
0x0006 (DSR2)
0x0007 (DSR3)
0x0008 (DSR4)
0x0009 (DSR5)
0x000A (DSR6)
0x000B (DSR7)
7
6
5
4
3
2
1
0
R
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
W
Reset:
x
x
x
x
x
x
x
x
Figure 16-34. Data Segment Registers (DSR0–DSR7) — Extended Identifier Mapping
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:
S12XE
products
in
208
MAPBGA
packages