Chapter 22 Timer Module (TIM16B8CV2) Block Description
MC9S12XE-Family Reference Manual Rev. 1.19
Freescale Semiconductor
803
22.3.2.14 Timer Input Capture/Output Compare Registers High and Low 0–7
(TCxH and TCxL)
Depending on the TIOS bit for the corresponding channel, these registers are used to latch the value of the
free-running counter when a defined transition is sensed by the corresponding input capture edge detector
or to trigger an output action for output compare.
Read: Anytime
Write: Anytime for output compare function.Writes to these registers have no meaning or effect during
input capture. All timer input capture/output compare registers are reset to 0x0000.
NOTE
Read/Write access in byte mode for high byte should takes place before low
byte otherwise it will give a different result.
Table 22-16. TRLG2 Field Descriptions
Field
Description
7
TOF
Timer Overflow Flag
— Set when 16-bit free-running timer overflows from 0xFFFF to 0x0000. Clearing this bit
requires writing a one to bit 7 of TFLG2 register while the TEN bit of TSCR1 is set to one (See also TCRE control
bit explanation.)
Module Base + 0x0010 = TC0H
0x0012 = TC1H
0x0014 = TC2H
0x0016 = TC3H
0x0018 = TC4H
0x001A = TC5H
0x001C = TC6H
0x001E = TC7H
15
14
13
12
11
10
9
0
R
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
W
Reset
0
0
0
0
0
0
0
0
Figure 22-22. Timer Input Capture/Output Compare Register x High (TCxH)
Module Base + 0x0011 = TC0L
0x0013 = TC1L
0x0015 = TC2L
0x0017 = TC3L
0x0019 = TC4L
0x001B = TC5L
0x001D = TC6L
0x001F = TC7L
7
6
5
4
3
2
1
0
R
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
W
Reset
0
0
0
0
0
0
0
0
Figure 22-23. Timer Input Capture/Output Compare Register x Low (TCxL)
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:
S12XE
products
in
208
MAPBGA
packages