Chapter 28 768 KByte Flash Module (S12XFTM768K4V2)
MC9S12XE-Family Reference Manual , Rev. 1.19
Freescale Semiconductor
1119
28.4.2.7
Program Once Command
The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the
nonvolatile information register located in P-Flash block 0. The Program Once reserved field can be read
using the Read Once command as described in
. The Program Once command must only
be issued once since the nonvolatile information register in P-Flash block 0 cannot be erased.
Upon clearing CCIF to launch the Program Once command, the Memory Controller first verifies that the
selected phrase is erased. If erased, then the selected phrase will be programmed and then verified with
read back. The CCIF flag will remain clear, setting only after the Program Once operation has completed.
The reserved nonvolatile information register accessed by the Program Once command cannot be erased
and any attempt to program one of these phrases a second time will not be allowed. Valid phrase index
values for the Program Once command range from 0x0000 to 0x0007. During execution of the Program
Once command, any attempt to read addresses within P-Flash block 0 will return invalid data.
Table 28-45. Program Once Command FCCOB Requirements
CCOBIX[2:0]
FCCOB Parameters
000
0x07
Not Required
001
Program Once phrase index (0x0000 - 0x0007)
010
Program Once word 0 value
011
Program Once word 1 value
100
Program Once word 2 value
101
Program Once word 3 value
Table 28-46. Program Once Command Error Handling
Register
Error Bit
Error Condition
FSTAT
ACCERR
Set if CCOBIX[2:0] != 101 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see
)
Set if an invalid phrase index is supplied
Set if the requested phrase has already been programmed
(1)
1. If a Program Once phrase is initially programmed to 0xFFFF_FFFF_FFFF_FFFF, the Program Once command will
be allowed to execute again on that same phrase.
FPVIOL
None
MGSTAT1
Set if any errors have been encountered during the verify operation
MGSTAT0
Set if any non-correctable errors have been encountered during the verify
operation
FERSTAT
EPVIOLIF
None
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:
S12XE
products
in
208
MAPBGA
packages