OSCx_CR field descriptions (continued)
Field
Description
Controls whether or not the external reference clock (OSCERCLK) remains enabled when MCU enters
Stop mode.
0
External reference clock is disabled in Stop mode.
1
External reference clock stays enabled in Stop mode if ERCLKEN is set before entering Stop mode.
4
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
3
SC2P
Oscillator 2 pF Capacitor Load Configure
Configures the oscillator load.
0
Disable the selection.
1
Add 2 pF capacitor to the oscillator load.
2
SC4P
Oscillator 4 pF Capacitor Load Configure
Configures the oscillator load.
0
Disable the selection.
1
Add 4 pF capacitor to the oscillator load.
1
SC8P
Oscillator 8 pF Capacitor Load Configure
Configures the oscillator load.
0
Disable the selection.
1
Add 8 pF capacitor to the oscillator load.
0
SC16P
Oscillator 16 pF Capacitor Load Configure
Configures the oscillator load.
0
Disable the selection.
1
Add 16 pF capacitor to the oscillator load.
22.8 Functional Description
This following sections provide functional details of the module.
22.8.1 OSC Module States
The states of the OSC module are shown in the following figure. The states and their
transitions between each other are described in this section.
Functional Description
KL02 Sub-Family Reference Manual, Rev. 2.1, July 2013
292
Freescale Semiconductor, Inc.