background image

 

5 Jumper/Switch 

Table 

The following table describes the function of the jumpers on the Fire Engine. 

 

Table 5.1: Jumper Switch Table 

 

Jumper Settings 

 

Function 

 

 

J14  

Jmp 2-4 

CAN Port 1 Non-terminated  
data line 

     

Jmp 4-6  

CAN Port 1 Terminated data 
line 

 

J14  

Jmp 1-3  

CAN Port 1 Non-terminated  
data line 

     

Jmp 3-5   

CAN Port 1 Terminated data 
line 

        
 

Zoom ColdFire Lite QuickStart Guide 

 

13

Summary of Contents for Logic Zoom ColdFire LITE M5474EVB

Page 1: ...developed by Zoom ColdFire Development Kit ColdFire LITEKIT QuickStart Guide...

Page 2: ...ions of a duly executed license or agreement to purchase or lease equipments The only warranties made by Logic Product Development if any with respect to the products described in this document are se...

Page 3: ...e Development Kit 8 4 2 1 dBUG ROM Monitor Power up 9 4 2 2 LogicLoader bootloader monitor Power up 9 4 3 Using the Development Kit with the P E ColdFire LITE BDM Interface 10 4 3 1 Using the BDM with...

Page 4: ...33 or 66MHz 3 3V Serial Ports One 115 2kbps RS 232 serial ports Two TTL serial ports Can 2 0b One port MCF5485 only USB USB 2 0 One High speed device on Fire Engine SPI RTC Network Support One RJ45 E...

Page 5: ...pters US UK EUR and Japan Warranty Card QuickStart Guide Packing List Third party development tools and software wrapped in individual CDs Note Avoid touching the MOS devices Static discharge can and...

Page 6: ...ote Zoom ColdFire LITE Development Kit QuickStart Guide LogicLoader User s Manual Software Development Tools Tera Term serial emulation program Cygwin and GNU Cross Development Toolchain Sample applic...

Page 7: ...this image Ethernet Port 0 bottom in this image 4 ATX Power Connector 5 5V Power In use appropriate power adaptor 6 System Reset Button 7 PCI Connector 8 Power On LED Important Note The ITX baseboard...

Page 8: ...DM Interface Connection Diagram Please ensure that your P E Shielded BDM Interface is properly connected Figure 2 3 P E Shielded BDM Interface Properly Connected to the Fire Engine Zoom ColdFire Lite...

Page 9: ...the Fire Engine downward on each connector until it is fully seated 3 Verify that the Hirose connectors on the Fire Engine and Mini ITX Baseboard have mated correctly To remove the Fire Engine carefu...

Page 10: ...pter into the power outlet and the 5V line output connector into the power connector on the baseboard 3 3 Power Supply The Fire Engine is equipped with 2 options for providing power 2 1 mm barrel conn...

Page 11: ...support any terminal emulation programs under Linux or Windows platforms Once the terminal emulation program has been installed open a new serial port connection using the port where the null modem s...

Page 12: ...and for ease of interfacing to LogicLoader To do so enter the command set baud 115200 at the dBUG prompt Next adjust the baud rate on your terminal emulation program to 115200 Then press System Reset...

Page 13: ...rface from P E Microcomputer Systems that can be used with a variety of development tools The installation and use of the cable may vary between different development tool vendors In order to use the...

Page 14: ...e the jumper as shown below Figure 4 2 Remove BDM Enclosure to change the Jumper 2 Next configure your jumper as presented in the figure below Figure 4 3 Jumper Setting for GNU Cross Development Toolc...

Page 15: ...not access the GiveIO device you must manually start the GIVEIO driver to give hardware access to GDB a To manually start GIVEIO in Windows 2000 go to Device Manager and show hidden devices by selecti...

Page 16: ...he Fire Engine Table 5 1 Jumper Switch Table Jumper Settings Function J14 Jmp 2 4 CAN Port 1 Non terminated data line Jmp 4 6 CAN Port 1 Terminated data line J14 Jmp 1 3 CAN Port 1 Non terminated data...

Page 17: ...warranty does not cover product damaged by ESD Approvals This product is compliant with emissions standard EN55022 level A and may be operated in industrial areas as defined by national regulations Th...

Page 18: ...0 Y Y MCF5475EFE 64 0 Y Y Y MCF5475FFE 128 32 Y Y Y When ordering Fire Engines with USB Host PCI slot is locked at 33 MHz Denotes the Fire Engine Configuration on M5475EVB Zoom ColdFire LITE Developm...

Page 19: ...Zoom ColdFire LITE Development Kit hardware LogicLoader Bootloader Monitor What does Logic Product Development NOT support See respective third party solutions for technical support Freescale s dBUG R...

Page 20: ...s Specification Table Logic offers the following Display Kits for use with the Application Development Kits Visit our website for current information on Zoom Display Kits Figure 10 2 Zoom Display Kits...

Page 21: ...oting from the CompactFlash interface on the Fire Engine This command makes that interface available to other commands through the file system If an ELF BIN RAW or S record image is stored on the Comp...

Page 22: ...sing the System Reset button see Figure 2 2 Q My CompactFlash connector does not work why A See Section 11 regarding CompactFlash functionality Q How do I use CPLD devices on the board A See Section 1...

Reviews: