Chapter 10 Freescale’s Scalable Controller Area Network (S12MSCANV2)
Freescale Semiconductor
MC9S12C-Family / MC9S12GC-Family
303
Rev 01.24
10.3.2.8
MSCAN Transmitter Interrupt Enable Register (CANTIER)
This register contains the interrupt enable bits for the transmit buffer empty interrupt flags.
NOTE
The CANTIER register is held in the reset state when the initialization mode
is active (INITRQ = 1 and INITAK = 1). This register is writable when not
in initialization mode (INITRQ = 0 and INITAK = 0).
Read: Anytime
Write: Anytime when not in initialization mode
Table 10-11. CANTFLG Register Field Descriptions
Field
Description
2:0
TXE[2:0]
Transmitter Buffer Empty
— This flag indicates that the associated transmit message buffer is empty, and thus
not scheduled for transmission. The CPU must clear the flag after a message is set up in the transmit buffer and
is due for transmission. The MSCAN sets the flag after the message is sent successfully. The flag is also set by
the MSCAN when the transmission request is successfully aborted due to a pending abort request (see
Section 10.3.2.9, “MSCAN Transmitter Message Abort Request Register (CANTARQ)
”). If not masked, a
transmit interrupt is pending while this flag is set.
Clearing a TXEx flag also clears the corresponding ABTAKx (see
Section 10.3.2.10, “MSCAN Transmitter
Message Abort Acknowledge Register (CANTAAK)
”). When a TXEx flag is set, the corresponding ABTRQx bit
is cleared (see
Section 10.3.2.9, “MSCAN Transmitter Message Abort Request Register (CANTARQ)
When listen-mode is active (see
Section 10.3.2.2, “MSCAN Control Register 1 (CANCTL1)
”) the TXEx flags
cannot be cleared and no transmission is started.
Read and write accesses to the transmit buffer will be blocked, if the corresponding TXEx bit is cleared
(TXEx = 0) and the buffer is scheduled for transmission.
0 The associated message buffer is full (loaded with a message due for transmission)
1 The associated message buffer is empty (not scheduled)
Module Base + 0x0007
7
6
5
4
3
2
1
0
R
0
0
0
0
0
TXEIE2
TXEIE1
TXEIE0
W
Reset:
0
0
0
0
0
0
0
0
= Unimplemented
Figure 10-11. MSCAN Transmitter Interrupt Enable Register (CANTIER)
Table 10-12. CANTIER Register Field Descriptions
Field
Description
2:0
TXEIE[2:0]
Transmitter Empty Interrupt Enable
0 No interrupt request is generated from this event.
1 A transmitter empty (transmit buffer available for transmission) event causes a transmitter empty interrupt
request.
Summary of Contents for MC9S12C Family
Page 689: ......