Chapter 11 Freescale’s Scalable Controller Area Network (S12MSCANV3)
S12ZVHY/S12ZVHL Family Reference Manual Rev. 1.05
428
Freescale Semiconductor
11.3.2.1
MSCAN Control Register 0 (CANCTL0)
The CANCTL0 register provides various control bits of the MSCAN module as described below.
NOTE
The CANCTL0 register, except WUPE, INITRQ, and SLPRQ, is held in the
reset state when the initialization mode is active (INITRQ = 1 and
INITAK = 1). This register is writable again as soon as the initialization
mode is exited (INITRQ = 0 and INITAK = 0).
Module Base + 0x0000
Access: User read/write
(1)
1. Read: Anytime
Write: Anytime when out of initialization mode; exceptions are read-only RXACT and SYNCH, RXFRM (which is set by the
module only), and INITRQ (which is also writable in initialization mode)
7
6
5
4
3
2
1
0
R
RXFRM
RXACT
CSWAI
SYNCH
TIME
WUPE
SLPRQ
INITRQ
W
Reset:
0
0
0
0
0
0
0
1
= Unimplemented
Figure 11-4. MSCAN Control Register 0 (CANCTL0)
Table 11-2. CANCTL0 Register Field Descriptions
Field
Description
7
RXFRM
Received Frame Flag
— This bit is read and clear only. It is set when a receiver has received a valid message
correctly, independently of the filter configuration. After it is set, it remains set until cleared by software or reset.
Clearing is done by writing a 1. Writing a 0 is ignored. This bit is not valid in loopback mode.
0 No valid message was received since last clearing this flag
1 A valid message was received since last clearing of this flag
6
RXACT
Receiver Active Status
— This read-only flag indicates the MSCAN is receiving a message
(1)
. The flag is
controlled by the receiver front end. This bit is not valid in loopback mode.
0 MSCAN is transmitting or idle
1 MSCAN is receiving a message (including when arbitration is lost)
5
CSWAI
(2)
CAN Stops in Wait Mode
— Enabling this bit allows for lower power consumption in wait mode by disabling all
the clocks at the CPU bus interface to the MSCAN module.
0 The module is not affected during wait mode
1 The module ceases to be clocked during wait mode
4
SYNCH
Synchronized Status
— This read-only flag indicates whether the MSCAN is synchronized to the CAN bus and
able to participate in the communication process. It is set and cleared by the MSCAN.
0 MSCAN is not synchronized to the CAN bus
1 MSCAN is synchronized to the CAN bus