Figure 21-30. Generic Flash Command Write Sequence Flowchart
Write to FCCOBIX register
Write: FSTAT register (to launch command)
Clear CCIF 0x80
Clear ACCERR/FPVIOL 0x30
Write: FSTAT register
yes
no
Access Error and
Protection Violation
Read: FSTAT register
START
Check
FCCOB
ACCERR/
FPVIOL
Set?
EXIT
Write: FCLKDIV register
Read: FCLKDIV register
yes
no
FDIV
Correct?
no
Bit Polling for
Command Completion
Check
yes
CCIF Set?
to indicate number of parameters
to be loaded.
Write to FCCOB register
to load required command parameter.
yes
no
More
Parameters?
Availability Check
Results from previous Command
Note: FCLKDIV must be
set after each reset
Read: FSTAT register
no
yes
CCIF
Set?
no
yes
CCIF
Set?
Clock Divider
Value Check