00:CF:52:35:00:01
MAC Address
192.168.1.3 for static implementation
IP Address
255.255.255.0
Mask Address
192.168.1.1
Gateway Address
192.168.1.3
Server Address to Connect to an Address
Static
Static or Dynamic Address
TCP Parameters
1234
TCP Port to Connect to
192.168.1.3
Client or server implementation
Configuration
Configuration or bridge Implementation
UART Parameters
First Port
Port
19200
Baudrate
NONE
Parity
8
Number of bits
1
Number of Stop bits
SW Flow Control
Flow Control
SPI Parameters
Second Port
Port
1 Mbps
Baudrate
Low
Polarity
Middle
Phase
Master
Master or Slave
Polling
Polling or Interrupt Handling
4.5 Serial Configuration Commands
In configuration mode, the serial configuration task is enabled. The purpose of this task is
to configure all the serial parameters stated in Section1.2
Key Features
. Default settings
are stated in
Table 4-2
. The configuration is made through a set of commands that are sent
using the UART or SPI interface. These commands are sent from the data terminal equipment
(DTE), like a PC to the MCF51CN128 reference design hardware.
Table 4-3
,
Table 4-4
, and
Table 4-5
list all available commands. For example, if the
board_get_uart_port command is requested, the serial interface must send the packet as
shown in
Figure 4-9
.
TCP/IP Applications Using the MCF51CN Family—Designer Reference Manual, Rev. 0, 12/2009
Freescale Semiconductor
36
Serial Configuration Commands