Memory Map/Register Definition
MCF52110 ColdFire® Integrated Microcontroller Reference Manual, Rev. 1
Freescale Semiconductor
11-3
Preliminary
11.2.1.1
RTC Hours and Minutes Counter Register (HOURMIN)
The real-time clock hours and minutes counter register (HOURMIN) is used to program the hours and
minutes for the TOD clock. It can be read or written at any time. After a write, the time changes to the new
value. A power-on reset (POR) sets the RTC to the reset values shown in
.
Figure 11-2. RTC Hours and Minutes Counter Register (HOURMIN)
IPSBAR
Offset: 0x03C0 (HOURMIN)
Access: User read/write
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
1
1
After power-on reset (POR)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
0
0
0
HOURS
0
0
MINUTES
W
0
0
0
?
?
?
?
?
0
0
?
?
?
?
?
?
Table 11-2. HOURMIN Field Descriptions
Field
Description
31–13
Reserved, should be cleared.
12–8
HOURS
Hour setting; can be set to any value between 0 and 23.
7–6
Reserved, should be cleared.
5–0
MINUTES
Minutes setting; can be set to any value between 0 and 59.