Real-Time Clock
MCF52110 ColdFire® Integrated Microcontroller Reference Manual, Rev. 1
11-6
Freescale Semiconductor
Preliminary
11.2.1.4
RTC Seconds Alarm Register (ALRM_SEC)
The real-time clock seconds alarm (ALRM_SEC) register is used to configure the seconds setting for the
alarm. The alarm settings can be read or written at any time.
Figure 11-5. RTC Seconds Alarm Register (ALRM_SEC)
IPSBAR
Offset: 0x03CC (ALRM_SEC)
Access: User read/write
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
0
0
0
0
0
0
0
0
0
0
SECONDS
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Table 11-5. ALRM_SEC Field Descriptions
Field
Description
31–6
Reserved, should be cleared.
5–0
SECONDS
Alarm seconds setting; can be set to any value between 0 and 59.