Real-Time Clock
MCF52110 ColdFire® Integrated Microcontroller Reference Manual, Rev. 1
11-12
Freescale Semiconductor
Preliminary
11.2.1.10 RTC Day Alarm Register (ALRM_DAY)
The real-time clock day alarm (ALRM_DAY) register is used to configure the day for the alarm. The alarm
settings can be read or written at any time.
Figure 11-11. RTC Day Alarm Register (ALRM_DAY)
11.2.1.11 RTC General Oscillator Count Registers (RTCGOCU and RTCGOCL)
The real-time clock general oscillator count registers (RTCGOCU and RTCGOCL) contain the upper and
lower 16 bits of a 32-bit field, RTCGOCNT. This field is used to control the 1 Hz clock and the sampling
clock as described in
Section 11.3, “Functional Description
Figure 11-12. RTC General Oscillator Count Upper Register (RTCGOCU)
IPSBAR
Offset: 0x03E4 (ALRM_DAY)
Access: User read/write
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
DAYSAL
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Table 11-11. ALRM_DAY Field Descriptions
Field
Description
31–16
Reserved, should be cleared.
15–0
DAYSAL
Day Setting of the Alarm. This field can be set to any value between 0 and 65535.
IPSBAR
Offset: 0x03F4 (RTCGOCU)
Access: User read/write
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
RTCGOCNT[31:16]
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Table 11-12. RTCGOCU Field Descriptions
Field
Description
15–0
RTCGOCNT[31:16]
RTC general oscillator count, bits 31:16. This field is used to control the 1 Hz clock and the sampling
clock as described in