Real-Time Clock
MCF52235 ColdFire® Integrated Microcontroller Reference Manual, Rev. 6
Freescale Semiconductor
8-4
8.2.3
RTC Hours and Minutes Alarm Register (ALRM_HM)
The real-time clock hours and minutes alarm (ALRM_HM) register is used to configure the hours and
minutes setting for the alarm. The alarm settings can be read or written at any time.
IPSBAR
Offset: 0x03C4 (SECONDS)
Access: User read/write
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
1
1
After power-on reset (POR)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
0
0
0
0
0
0
0
0
0
0
SECONDS
W
0
0
0
0
0
0
0
0
0
0
?
?
?
?
?
?
Figure 8-3. RTC Seconds Counter Register (SECONDS)
Table 8-3. SECONDS Field Descriptions
Field
Description
31–6
Reserved, should be cleared.
5–0
SECONDS
Seconds setting; can be set to any value between 0 and 59.
IPSBAR
Offset: 0x03C8 (ALRM_HM)
Access: User read/write
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
0
0
0
HOURS
0
0
MINUTES
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Figure 8-4. RTC Hours and Minutes Alarm Register (ALRM_HM)
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:MCF52234CVM60,
MCF52235CVM60