Analog-to-Digital Converter (ADC)
MCF52235 ColdFire® Integrated Microcontroller Reference Manual, Rev. 6
Freescale Semiconductor
28-20
28.4.13 Voltage Reference Register (CAL)
In earlier series, this register supported ADC calibration and had a different name. Improvements in ADC
performance have eliminated the need for on-chip calibration support, hence the new name.
1
PD1
Manual Power-Down for Converter B bit. This bit forces Converter B to power-down. Setting PD1
powers-down converter B immediately. The results of a scan using converter B is invalid when PD1 is set.
When PD1 is cleared, converter B is continuously powered-up (APD = 0) or automatically powered-up when
needed (APD = 1).
0 Power-up ADC converter B
1 Power-down ADC converter B
Note: When clearing PD1 in any power mode except auto power-down (APD = 1), wait PUDELAY ADC clock
cycles before initiating a scan to stabilize power levels within the converter. The PSTS1 bit can be
polled to determine when the PUDELAY time has elapsed. Failure to follow this procedure can result
in loss of accuracy of the first two samples.
0
PD0
Manual Power-Down for Converter A bit. This bit forces Converter A to power-down. Setting PD0
powers-down converter A immediately. The results of a scan using converter A is invalid when PD0 is set.
When PD0 is cleared, converter A is continuously powered-up (APD = 0) or automatically powered-up when
needed (APD = 1).
0 = Power-up ADC converter A
1 = Power-down ADC converter A
Note: When clearing PD0 in any power mode except auto power-down (APD = 1), wait PUDELAY ADC clock
cycles before initiating a scan to stabilize power levels within the converter. The PSTS0 bit can be
polled to determine when the PUDELAY time has elapsed. Failure to follow this procedure can result
in loss of accuracy of the first two samples.
IPSBAR
Offset: 0x19_0054 (CAL)
Access: read/write
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
SEL_VREFH SEL_VREFL
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Figure 28-17. Voltage Reference Register (CAL)
Table 28-19. CAL Field Descriptions
Field
Description
15
SEL_VREFH
Select V
REFH
Source bit. This bit selects the source of the V
REFH
reference for conversions.
0 VRH
1 AN2
14
SEL_VREFL
Select V
REFL
Source bit. This bit selects the source of the V
REFL
reference for conversions.
0 VRL
1 AN6
13–0
Reserved, should be cleared.
Table 28-18. POWER Field Descriptions (continued)
Field
Description
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:MCF52234CVM60,
MCF52235CVM60