This addendum document describes corrections to the 

MPC5607B Microcontroller Reference Manual

, order 

number MPC5607BRM. For convenience, the addenda 
items are grouped by revision. Please check our website 
at http://www.freescale.com/powerarchitecture for the 
latest updates.

The current version available of the 

MPC5607B 

Microcontroller Reference Manual

 is Revision 7.1.

MPC5607B Microcontroller 
Reference Manual Addendum

by: Microcontroller Solutions Group

1

Addendum List for Revision 7.1  . . . . . . . . . . . . . .  2

2

Revision History  . . . . . . . . . . . . . . . . . . . . . . . . .  10

Summary of Contents for MPC5607B

Page 1: ...ference Manual order number MPC5607BRM For convenience the addenda items are grouped by revision Please check our website at http www freescale com powerarchitecture for the latest updates The current...

Page 2: ...he MMU Chapter 6 Clock Description page 132 Add Note to Section 6 8 4 1 Crystal clock monitor Note Functional FXOSC monitoring can only be guaranteed when the FXOSC frequency is greater than FIRC 2RCD...

Page 3: ...be set in the programmer s model but it would be unclear whether the actual link was made before the channel retired The coherency model in Table 16 24 is recommended when executing a dynamic channel...

Page 4: ...model are shown in the following subsections Method 1 has the advantage of reading the major linkch field and the e_sg bit with a single read For both dynamic channel linking and scatter gather reque...

Page 5: ...unique TCD ID in the TCD major linkch field for each TCD associated with a channel using dynamic scatter gather 2 Write 1b to theTCD d_req bit Note Should a dynamic scatter gather attempt fail setting...

Page 6: ...ttempt fail setting the d_req bit will prevent a future hardware activation of this channel This stops the channel from executing with a destination address daddr that was calculated using a scatter g...

Page 7: ...the latest message is always available to the application If the buffer lock function is enabled LINCR1 RBLM 0 the most recent message is discarded and the previous message is available in the buffer...

Page 8: ...Clocking Scheme to read This clock selection feature may not be available in all MCUs A particular MCU may not have a PLL in which case it would have only the oscillator clock or it may use only the...

Page 9: ...ompletion if the ADC is shut down while performing a CTU triggered conversion the CTU is not notified and will not be able to trigger further conversions until the device is reset Chapter 30 Flash Mem...

Page 10: ...e manual addendum document Chapter 32 Register Protection page 954 In Table 32 5 Protected registers change the module base address for the CMU_CSR register from C3FE00E0 to C3FE0000 Table 2 Revision...