16
EN
SETTINGS for
Fresh F100 T
When setting TIMER.
DISCONNECT THE POWER TO THE FAN.
TIMER SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION.
1.
Press the two clamps on to the base of the fan (see Figure 2) and remove the cover from
the chassis.
2.
The control is set at the factory to approx. 15 minutes overrun time.
The overrun time period can be adjusted from 5 to 30 minutes.
Note that the exact min / max time may vary between products.
3.
To reduce operating time:
Use a small screwdriver to turn the potentiometer Fig.8. COUNTERCLOCKWISE.
4.
To increase operating time:
Use a small screwdriver to turn the potentiometer Fig.8. CLOCKWISE.
5.
Replace the fan cover, making sure the hooks lock the cover securely. Turn on the power.
SETTINGS for
Fresh F100 TH
When setting the starting point for MOISTURE and changing the jumpers.
DISCONNECT THE POWER TO THE FAN.
TIMER AND MOISTURE LEVEL SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION.
The fan contains a built-in humidity detector that automatically sets the fan to full speed when
the relative humidity (RH) of the room increases. The fan continues to run until the room RH falls.
The fan also has a built-in timer function which gives a fixed overrun time of approx. 15 minutes.
The timer can be deactivated by removing jumper JP1, (Fig. 9).
1.
Press the two clamps on to the bottom of the fan (see Figure 2) and remove the cover from
the chassis.
2.
To increase the START POINT, turn the potentiometer clockwise. This reduces the internal
setpoint for relative humidity at which the fan is switched on. (Fig. 9)
3.
To reduce the START POINT, turn the potentiometer counterclockwise. This increases the
internal setpoint for relative humidity at which the fan is switched on. (Fig. 9)
The integrated pull cord activates the internal 15-minute timer. The timer can be interrupted by
pulling on the pull cord again. The pull cord can be removed by cutting the cord.
COMFORT MODE (TH model only)
The TH model includes comfort mode, which is activated by holding the pull cord firmly for 5 seconds.
The function delays activation of the LS input for a maximum of 20 minutes to reduce noise and cold draughts
when taking a bath. When the LS is switched off, the fan will be switched on for the same period that the LS
would have been active (up to 20 minutes), plus the overrun time if selected
(15 minutes).
The LED flashes slowly repeatedly (every 4 seconds) while counting down the comfort mode.
The LED changes from flashing to constant LED when LS boost is activated.
The fan’s internal humidity sensor is deactivated in comfort mode.
This function is reset if a power failure occurs.
SPEED SELECT (TH model only)
The fan can be set to high or low speed depending on the installation requirements.
The fan is factory-set to low speed with jumper JP2 fitted.
To activate the high speed setting, remove jumper JP2. (Fig. 9)